4.2 Terminal board J2 (outputs)
OUT 1 - Output 1 open-collector GND (terminal 13): The output can
be set in one of the functions described in the Advanced Configuration
04
(par. 6). The default value is
load: 24 VDC with 100 mA.
OUT 2 - Output 2 open-collector GND (terminal 15): The output can
be set in one of the functions described in the Advanced Configuration
(par. 6). The default value is
24 VDC with 100 mA.
OUT 3 - Output 3 open-collector GND (terminal 17): The output can
be set in one of the functions described in the Advanced Configuration
19
(par. 6). The default value is
24 VDC with 100 mA.
OUT 4 - Relay output 4 (terminals 19, 20, 21): The output can be
set in one of the functions described in Advanced Configuration (par.
01
6). The default value is
- Arm ILLUMINATION. Maximum load:
24 VDC with 800 mA.
B680H
TX CL
1
2
Fig. 24
Fig. 24
TX CL
1
2
RX CL
1
2
3
4
5
Fig. 25
Fig. 25
GND +24
Fig. 26
Fig. 26
- Arm OPEN or in
PAUSE.
Maximum
03
- CLOSED Arm. Maximum load:
- WARNING LAMP. Maximum load:
4.3 Terminal board J3 (external fl ashing lamp)
LAMP: to these terminals you can connect a 24VDC FAACLED
external flashing lamp. The integrated flashing traffic light must be
connected independently to connector J18.
The 24V FAACLIGHT with incandescent lamp cannot
be connected to the J3 connector
4.4 Terminal board J4 (loop detector)
LOOP 1: magnetic loop LOOP 1
(OPEN, terminals 24-25): for OPENING.
GND
LOOP 2: magnetic loop LOOP 2
+24
(SAFETY/CLOSE, terminals 26-27): for SAFETY/CLOSING.
4.5 Connector J5 (Motor)
Rapid connector for connecting the motor.
4.6 Connector J17 (Encoder)
The B680H barrier is equipped with a device for detecting the position
and speed of the arm to ensure greater anti-crushing safety thanks to
the possibility of reversing the direction of movement the moment an
obstacle is detected. This device is connected to the board with J17.
4.7 Connector J10 (Radio)
Used for the rapid connection of the RP / RP2 Receivers. If a
2-channel receiver is used, like the RP2, it will be possible to directly
GND
command OPEN and CLOSE movements from a 2-channel radio
control. If a 1-channel receiver is used, like the RP, it will only be
+24
possible to command OPEN.
GND
+24
The radio board should be inserted and removed ONLY
with power OFF
4.8 Connector J11 (Arm break-out sensor)
Designed for connecting the break-out sensor for the pivoting arm
(if present). The sensor is optional. If it is not present, do not remove
the installed jumper.
4.9 Connector J12 (Battery backup)
This is where the optional battery backup is connected. The battery
will ensure the B680H operation in case of temporary loss of the
main power supply.
4.10 Connector J13 (36VDC Power Supply)
This factory-wired connector powers the E680 board.
The terminal shown in Fig. 21 ref.
to the earth ground to minimize electrical noise
4.11 Connector J18 (fl ashing traffi c light)
This is where the flashing traffic light built into the barrier cover is
connected. The flashing traffic light visually signals barrier movement
and, if needed, can control access to the property using the different
light colors.