6. Advanced Confi guration
To access Advanced Configuration, press F and, while holding it,
+
also press
:
+
•
when
is released, the number of the first available function
will appear
•
when F is also released, the value is displayed, and can be
+
-
changed using
and
•
pressing F again, and holding it, the name of the next parameter
will be displayed; when released, the value can be changed
+
-
using
and
•
once the last function has been reached, pressing F makes it
possible to either save the previously changed parameters or exit
without saving the changes; the display will go back to showing
the status of the inputs.
ADVANCED CONFIGURATION
Display
Function
Opening motor force
FO
Adjusts the thrust of the motor during the ope-
ning phase.
00
Minimum power
50
Maximum power
Closing motor force
FC
Adjusts the thrust of the motor during the closing
phase.
00
Minimum power
50
Maximum power
Pre-flashing
PF
This parameter is used to activate the flashing
lamp for 5 seconds before the selected
movement.
no
disabled
OC
before each movement
CL
before each closing movement
OP
before each opening movement
PA
only at the end of the pause
Pre-flashing time
tP
Pre-flashing time expressed in seconds.
00
minimum pre-flashing
10
maximum pre-flashing
B680H
Display
Function
Sensitivity of obstacle during closing
oc
This determines the sensitivity to an obstacle
before reversing takes place.
01
Minimum sensitivity
50
Maximum sensitivity
Output 1
o1
Setting this function makes it possible to modify
the signal type of output 1, allowing high
connection flexibility with external devices.
00
Failsafe
0 1
TYPE 1 ARM LIGHTS MODE: output
active when arm closed, disabled with
arm open or paused, intermittent when
moving. (Use with OUT5)
02
TYPE 2 ARM LIGHTS MODE: fl ashing
Default
output during opening, closing and with
rod closed or stopped. inactive with rod
open or paused. (Use with OUT5)
40
03
Arm CLOSED
04
Arm OPEN or in PAUSE, it goes off
during closing pre-fl ashing.
05
Arm in OPENING MOVEMENT,
including pre-fl ashing.
06
Arm in CLOSING MOVEMENT,
40
07
Arm STATIONARY
08
Arm in EMERGENCY mode
09
LOOP1 engaged
10
LOOP2 engaged
no
11
OPEN for E680 slave
12
CLOSE for E680 slave
13
Beam RELEASED
14
Not used
15
Not used
16
FCA engaged
17
FCC engaged
18
Interlock
19
WARNING LAMP: on during opening
and pause, fl ashing when closing, off
00
when the automated system is closed
20
Battery operation
Output 1 Polarity
P1
Allows setting of the output polarity:
Y
output NC
no
output NO
NOTE: if the output setting is
keep the value set to
Output 2
o2
Output 2 signal type, see "Output 1"
24
including pre-fl ashing.
00
(Failsafe),
no
532159 - Rev.C
Default
30
04
no
03