Display
Function
Loop 2
L2
Activating this parameter, any loop that is
connected to the Loop 2 input will serve as a
SAFETY/CLOSE function.
Y
Loop 2 enabled
no
Loop 2 disabled
(see note regarding Loop 1)
Loop 1 sensitivity
S1
Adjusts the sensitivity of the vehicle detection
loop
00
Minimum sensitivity
10
Maximum sensitivity
Loop 2 sensitivity
S2
Adjusts the sensitivity of the vehicle detection
loop
00
Minimum sensitivity
10
Maximum sensitivity
Motor movement
Mt
Using the function provided by this para-
meter makes it possible to manually move
the barrier bar, operating as dead-man.
Pressing + will open the automated system,
pressing - causes the automated system to
close.
oP
pressing +, open
cL
pressing -, close
Learning
tL
Working time and limit switch learning (see
section 7.2)
SYSTEM STATUS:
St
This allows you to choose whether to save the program-
med data upon quitting.
Y
= quit and save the data
no
= quit without saving the data
After quitting the program, press the F key to display the
status of the automated system
00
Beam closed
01
Beam open
02
Stationary ready to open
03
Stationary ready to close
04
Automated system paused
05
Opening
06
Closing
07
Failsafe in progress
08
2-EASY device verification in progress
09
Pre-flashing then OPENS
10
Pre-flashing then CLOSES
11
EMERGENCY Open
St
You can go to
then -.
B680H
Default
no
05
05
--
--
at any time by pressing F and
The system status information
installation process to make sure that the control board logic and the
actual barrier movement are consistent.
If, for example, the barrier's status is CLOSED, the display MUST read
00
. When the OPEN command is received, the display will change
09
to
, if pre-flashing is enabled, or directly to
movement) to then display
reached).
Example of a status sequence displayed starting from a closed barrier
The sequence does not include statuses
correspond to pre-flashing when opening and closing,
respectively.
00
Beam closed
01
Beam open /
04
Pause
5.2 Changing the predefi ned parameters set
The E680 board features six sets of pre-defined configurations that
allow rapid adapting to the size of the arm installed. To select one of
the available configurations change the parameter
06
value of
to that corresponding to the barrier configuration (arm
length, type and quantity of accessories installed) given in Table 3 or
Table 4 on the next page (for example, choose the default
arm type "L" of 17.4 ft (5.3 m) with lights).
To complete the configuration, it is necessary to exit the Basic
Configuration menu by pressing "F" until parameter
or by pressing "F" and "-"
This operation changes the value of the parameters
So
SC
and
in Basic confi guration and
in Advanced confi guration, setting them on the default
values as shown in the tables in paragraph 6.3.
Setting a set of pre-defi ned parameters that does not
correspond to the actual confi guration of the barrier could
cause irreversible damage to the automated system,
in particular if the default corresponds to a arm length
shorter than the actual one.
22
St
is very useful during the the
05
(the OPENING
01
once the position of barrier OPEN is
09
and
05
Opening
06
Closing
cF
from the default
St
FO
532159 - Rev.C
10
which
04
for a
is reached
FC
oc
,
,