Chapter II
Number of counts :
50 000 (or 5 000, refer to §. 3.4.)
Range selection :
automatic or manual for the 500 µA, 5 mA, 50 mA, 500 mA ranges
Additional error according to crest factor :
(Specification given full scale for a squarewave signal pulse 200 µs wide)
Additional error in I
AC+DC
5.5.

Resistance / Continuity

Ranges
Accuracy
500 Ω /
0.07% R + 5 D
5 kΩ
50 kΩ
0.07% R + 2 D
500 kΩ
0.3% R + 2 D
5 MΩ∗∗
50 MΩ∗∗
1% R + 2 D
∗ Overload protection can be reset automatically.
∗∗ It is highly recommended to use very short and shielded test leads for measurements in this
range (> 1 MΩ).
Number of counts :
Range selection :
Maximum open circuit voltage :
Detection threshold in continuity mode :
Response time in continuity mode :
5.6.

Capacitance

Note
Discharge all condensers before taking measurements.
Ranges
Accuracy
50 nF∗∗
500 nF
5 µF
1% R + 2 D
50 µF
500 µF
5000 µF
50 mF
∗ Overload protection can be reset automatically.
∗∗ It is highly recommended to use very short and shielded test leads for measurements in this
range.
Number of counts :
Range selection :
Maximum open circuit voltage :
Portable digital multimeter
0.2 % for a crest factor of 2 to 3
0.5 % for a crest factor of 3 to 6
with a direct current at input : 1 %
Measurement
current
1 mA
100 µA
10 µA
1 µA
100 nA
50 nA
50 000 (or 5 000, refer to §. 3.4.)
automatic or manual (fixed in continuity mode)
7 V
10 Ω to 20 Ω
1 ms
Max.
Measurement
measurement
current
time
100 nA
1 µA
0.5 s
10 µA
100 µA
1.5 s
1 mA
3 s/mF
5 000
automatic or manual
7 V
Resolution
Protection∗
10 mΩ
100 mΩ
1 Ω
600 V
RMS
10 Ω
100 Ω
1 kΩ
Resolution
Protection∗
10 pF
100 pF
1 nF
600 V
RMS
10 nF
100 nF
1 µF
10 µF
33