Identification Of The Components - Elkron DT600 Notice D'installation

Détecteur radio à double technologie pour l'extérieur en rideau
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

ENGLISH
The DT600 is a dual technology detector for exterior use with a curtain effect and passive infra-red (PIR) and microwave motion
sensor capable of detecting movements in an assigned area and indicate them to the control panel to activate the intrusion alarm.
The base of the product has holes to allow installation on a flat surface, using - if necessary - the 90° bracket and an articulation
(optional).

Identification of the components

1. LED filter screw covers
2. Closure screws
3. Card-fastening screws
4. Lens
5. Anti-opening tamper
6. Dip Switch (never use 4 and 5: always
OFF)
7. Detector capacity trimmer
8.
PIR sensitive element
9. Detector LED
10. Battery compartment
11. Learning Button
12. Internal LED for the learning operations and battery
signals
13. Jumper tamper (removal protection)
Intended to connect the removal protection (optional, not
included)
14. For future uses (do not modify the position)
Initialisation phase
This condition is activated automatically when the battery is enabled and at each opening/closure of the front panel. It will remain
in this mode for 60 seconds, during which the detector is not active.
Test mode (Walk Test)
By opening the front panel of the sensor, after having waited for the initialisation phase to finish, the Test Mode is launched and
lasts about 4 minutes. In this condition the cut-off time is disabled, while the LED of the detector of the alarm signal is automatically
enabled.
When in this mode, the detection tests can be conducted to verify the alarms by turning on the LED and the radio connection
capacity can be tested (for details, consult the manual for the control unit). After 4 minutes, the sensor will automatically revert to
operating condition. If the front panel is reopened, the test mode (Walk Test) will be automatically reactivated, after the initialisation
time.
Cut-off time and low-consumption operation
To avoid high consumption of the battery, the detector automatically inhibits consecutive alarm signals for a set cut-off time. In
this way, the continuous movement in front o fa detector will not deplete the battery uselessly. Then between one alarm and the
next one there will be a period of silence equal to the cut-off time. This feature is not enabled during the test mode (Walk Test).
There is a choice of two cut-off times:
- Dip Switch N° 2 in OFF position 4 min (Default)
- Dip Switch N° 2 in ON position 8 min
Supervision Function
When the detector is in normal functioning mode, it periodically conducts a self-diagnostic test, transmitting a random
supervision signal every 30-50 minutes.