PARTS IDENTIFICATION
Remove cover by loosening the bottom fixing screw revealing the inside of the Door Contact.
LED indicator
Tamper Switch
Jumper On
The jumper link is inserted.
JP1 = Test / Normal Mode Jumper
Jumper (ON): Door Contact is in Test mode.
Jumper (OFF): Door Contact is in Normal mode (Factory default).
JP2 = Supervision Enable / Disable Jumper Switch
Jumper (ON): Supervision disabled (Factory default).
Jumper (OFF): Supervision enabled
JP3 = Internal Magnet Switch Bypass Jumper Switch
Jumper (ON): the internal magnet switch is bypassed. Only the device connected to the Extension
Terminal will activate the Door Contact.
Jumper (OFF): the internal magnet switch is in use (Factory default).
JP4 = Door Close Confirmation Enable / Disable Jumper Switch
Jumper (ON): Door Contact will not send Door Close signal to Control panel.
Jumper (OFF): Door Contact will send Door Close signal to Control panel (Factory default).
LED INDICATOR
•
In Normal operation mode, the LED indicator remains off except in the following situations:
o Cover is opened and the tamper switch is violated, LED will light.
o A Tamper Condition persists or Door Contact is in Low battery condition, every time the Door
Contact is activated, the LED will light.
•
However, if the Door Contact is in Test mode, the LED will light every time it is activated.
DOOR CONTACT (DC200)
CONTACT D'OVERTURE (DC200)
TÜRKONTAKT (DC200)
Learn / Test button
Extension Terminal
Jumper Off
If the jumper link is removed or "parked" on one pin.
1/8