3.3 Datas
Typ
Nennwärmeleistung
Heating capacity (m
-under favourable
-less favourable
-not favourable heating circumstances
according to 18893/TAB2 DIN standard
Flue gas values:
Flue gas stream:
Flue gas temperature spigot:
Min. pressure at nominal performance:
CO (relating 13% O2):
Dust (relating 13% O2):
Efficiency:
Energy efficiency class
Energy efficiency index (EEI)
All information provided by the exhaust gas values are based on the EN 13240 under stationary labor-
atory conditions. We reserve the right to make changes which relate to technical advances and / or to
an improvement in quality. We accept no liability for printing errors and changes which occur after
printing.
4. Disposal of the device after wear
The device contains no hazardous materials, it is recommended to disassemble the device after the
wear and deposit the parts in appropriate landfill.
Haus – und Küchentechnik GmbH
Adalperostraße 86
D – 85737 Ismaning
Telefon +49 (0)89 32084-0
Telefax +49 (0)89 32084-294
www.wamsler.eu
3
)
fuel:
30
18820 PYLON
6,2 kW
144
84
58
wood
5,4 g/s
327 ˚C
12 Pa
≤ 1250 mg/m³
≤ 0,10 %
≤ 40 mg/m³
≥ 80,7%
A+
≥ 107