3.2 Datas
Type
Nominal performance
Heating capacity (m
-under favourable
-less favourable
-not favourable heating circumstances
according to 18893/TAB2 DIN standard
Flue gas values:
Flue gas stream:
Flue gas temperature:
Min. blast pressure at performance:
dust (relating to 13% O²)
CO (relating to 13% O²)
efficiency
All information provided by the exhaust gas values are based on the EN 13240 under stationary
laboratory conditions
3
)
fuel:
40
TYP108 81 DELTA
8 kW
182
105
71
wood / brown coal
7,6 / 6,6 g/s
260 / 250˚C
12 Pa
< 40 mg/m³
980 / 647 mg/m³
81,5 / 82,4 %