3.2 Datas
Type
Nominal performance
Heating capacity (m
-under favourable
-less favourable
-not favourable heating circumstances
according to 18893/TAB2 DIN standard
Flue gas values:
Flue gas stream:
Flue gas temperature:
Min. blast pressure at performance:
dust (relating to 13% O²)
CO (relating to 13% O²)
CO
NOx
OGC
efficiency
All information provided by the exhaust gas values are based on the EN 13240 under stationary
laboratory conditions
Wamsler bioenergy GmbH
Adalperostraße 86
D - 85737 Ismaning
Telefon +49 (0)89 32084-0
Telefax +49 (0)89 32084-294
www.wamsler.eu
We reserve the right to make changes which relate to technical advances and / or to an improve-
ment in quality. We accept no liability for printing errors and changes which occur after printing.
3
)
fuel:
39
TYP 113 91 ICON
8 kW
182
105
71
wood / brown coal
7,3 / 7,2 g/s
301 / 306 °C
12 Pa
35 / 35 mg/Nm
0,09 / 0,07 %
1143 / 814 mg/Nm
690 / 479 mg/MJ
61 / 50 mg/MJ
35 / 40 mg/MJ
81,3 / 80,4 %
3
3