3.3 Datas
Type
Nominal performance
Heating capacity (m
-under favourable
-less favourable
-not favourable heating circumstances
according to 18893/TAB2 DIN standard
Flue gas values:
Flue gas stream:
Flue gas temperature:
Min. blast pressure at performance:
CO (relating to 13% O²)
dust (relating to 13% O²)
efficiency
All information provided by the exhaust gas values are based on the EN 13240 under stationary
laboratory conditions
3
)
fuel:
TYP108 50 / 51 / 52 / 53 / 56 / 57
37
6,5 kW
132
78
52
wood / brown coal
7,5 g/s
290 ˚C
12 Pa
≤ 40 mg/m³
959 / 813 mg/m³
≥ 78 % / 74,5 %