Tips For Flush Mounting; Electrical Connection - De Dietrich DTE410 Guide D'installation Et D'utilisation

Table de cuisson
Masquer les pouces Voir aussi pour DTE410:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

All manuals and user guides at all-guides.com
99632084_ML_A.qxd
20/01/05
1 1 / / INSTALLING YOUR APPLIANCE
• • TIPS FOR FLUSH MOUNTING
Underside view
A
of the housing
Fig. 01
A
A
Mounting brackets
Fig. 02
Mounting brackets
Place your hob in the opening of the support
cabinet, carefully pulling the table toward you.
Reposition the burner heads, burner covers
and pan supports on the hob.
Connect your hob to the gas supply (See
"Gas Connection" chapter) and to the power
supply (See "Electrical Connection" chapter).
If you wish, you can immobilise the hob using
the four mounting brackets delivered with a
screw (Fig. 02) to attach them to the four
corners of the housing. Y Y o o u u m m u u s s t t u u s s e e t t h h e e
h h o o l l e e s s p p r r o o v v i i d d e e d d f f o o r r t t h h i i s s p p u u r r p p o o s s e e , , a a c c c c o o r r d d i i n n g g t t o o
t t h h e e d d i i a a g g r r a a m m a a b b o o v v e e (Fig. 01) . .
S S t t o o p p s s c c r r e e w w i i n n g g w w h h e e n n t t h h e e m m o o u u n n t t i i n n g g b b r r a a c c k k e e t t
s s t t a a r r t t s s t t o o b b e e c c o o m m e e d d e e f f o o r r m m e e d d . .
D D o o n n o o t t u u s s e e a a s s c c r r e e w w d d r r i i v v e e r r . .
13:30
Page 26

ELECTRICAL CONNECTION

• •
A
Your hob is sold with a power cable (type
H05V2V2F - T90, cross-section 1 mm²) with
three conductors (phase + ground + neutral).
After-sales service reference: 77X3767
(6470.1516). It must be connected to a
220-240 V ~
standardised CEI 60083 electrical outlet with
phase + ground + neutral or or an all-pole cut-
off device with a minimum distance between
contact openings of 3.5 mm.
The plug of the electrical outlet must be
accessible after installation.
C C
A A B B L L E E C C R R O O S S S S
A
H05V2V2F - T90
cable
Cross-section of
conductors in mm²
Fuse
Warning
The safety wire (green-yellow) is
connected to the appliance's ground
terminal
ground lead
The fuse in your set-up must be
10 amperes.
If the power cable is damaged, it must be
replaced by a cable or a special kit
available from the manufacturer or its
After-Sales Service Department.
Tip
In order to easily locate the reference
information for your appliance, we
recommend that you note them on the
"After-Sales Service Department and
Customer Relations" page (this page also
explains to you where to find this
information on your appliance).
26
monophase
grid
via
a
- -
S S E E C C T T I I O O N N T T O O B B E E U U S S E E D D
2 2 2 2 0 0 - - 2 2 4 4 0 0 V V ~ ~ 5 5 0 0 H H z z
g g a a s s a a n n d d d d u u a a l l
3 conductors,
including one
ground wire
1
10 A
and must be connected to the
of the electrical set-up.