Storage
o In case of longer inactivity period clean the device according to the description above
and store in dry and clean place, protected from frost, sunlight, and out of reach of
children. Do not place any heavy objects on the device.
8. Possible Malfunctions
CAUTION!
In the event of malfunctions during use immediately remove the plug
from the socket.
In case of anomalies use the table below before calling the service company or
informing the vendor.
FAILURE
The device is not
working
The device is
turned on but the
control light is off.
The device
turns off.
When the anomalies cannot be removed:
set the temperature controller in position
-
from the power supply (pull the plug!),
do not open the housing,
-
contact the service company or the vendor.
-
All manuals and user guides at all-guides.com
CAUSE
• The plug is not connected
to the socket.
• The house electric system
protection has been acti-
vated due to operation of
many high-power devices.
•
The temperature controller
is in position
• Damaged control light.
•
Incorrect setting of
temperature controller.
•
The protection against dry
operation has been
activated due to lack or
insufficient amount of
water in the tank.
SOLUTION
•
Connect the plug to the
electric socket.
•
Disconnect the device
from the power supply.
Then reset the fuse.
•
Set the temperature
.
controller in desired
position.
• Contact the vendor.
•
Set the temperature
controller in appropriate
position.
•
Wait for the device to cool
down and pour the water.
and disconnect the device
- 39 -