Télécharger Imprimer la page

GYS TIG 168 DC HF Mode D'emploi page 13

Masquer les pouces Voir aussi pour TIG 168 DC HF:

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 1
Recommended combinations / Electrode grinding
Current (A)
0,5-5
10-130
4-6,5
130-200
> 6.5
> 200A
To optimise the welding process, it is recommended to grind the electrode prior to welding as described in the
diagram below :
d
Trigger command connector
The trigger command socket is laid out in the following way:
DUTY CYCLE
The welding unit describes an output characteristic of a "constant current". The duty cycles following the norm
EN60974-1 (at 40°C on a 10mn cycle) are indicated in the table below :
X% @
21%
60%
100%
X% @
100%
Note : The machines' duty cycle has been tested at room temperature (40°C) and has been determined by
simulation.
Ø Electrode (mm)
= Ø wire (filler metal)
1,6
2,4
3,2
L = 3 x d for a low current
L = d for a high current
L
l
 Switch GND + Potentiometer
 Cold current button
 Welding torch button
 Cursor / potentiometer
 +5V potentiometer 10 KΩ
TIG 168
I max
X% @
I max
160A
15%
160A
100A
60%
80A
90A
100%
70A
TIG 200 (110V)
I max
X% @
I max
26%
180A
30%
120A
60%
115A
60%
90A
100A
100%
80A
Ø Nozzle (mm)
9,8
11
12,7
TIG 200
TIG 200 (230V)
X% @
I max
30%
200A
60%
140A
100%
125A
Flow rate (Argon L/mn)
6-7
7-8
8-9
TIG 168
 Switch GND
 Cold current button
 Welding torch button
2
3
1
4
5
X% @
I max
20%
200A
60%
125A
100%
110A
13/56

Publicité

loading

Ce manuel est également adapté pour: