4.1.3
Installation example bituminous membrane (floor slab with separating layer)
1 Staufix FKA
2 Seal set art. no. 83073: extension
section with flange and counter-
flange (for connection to an on-site
sealing sheet)
3 Extension section art. no. 83070
a Floor covering
f Protective con-
crete
b Screed
g Control unit
c Insulation
h Cable conduit
d Concrete floor
BWS* Rated water
level
e Waterproofing
layer
4.2
Connection of socket and spigot
Heed the following requirements for positioning the drain
body:
Observe a calming section of 1 m upstream and down-
stream of the system.
Maintain clearance to the wall and fixed objects to guar-
antee access.
010-842_01
If necessary, attach socket (1) and spigot (2) on the drain
body using turn fasteners (see installation instructions for
socket/spigot).
Check in both cases whether the turn fastener is closed
and the socket and/or spigot is fitted flush!