5
Electrical installation
Wiring
X3/
Signal
type
62
Analog
output
7
-
8
Analog
input
9
-
20
-
28
3)
E1
3)
E2
Digital
inputs
E3
E4
39
-
A1
Digital
output
59
-
1)
Output level 0 ... +10 V: Adapt offset (C0109/C0422) and gain (C0108/C0420)
2)
Adjust offset (C0026) and gain (C0027) separately for each function module ...
- after replacing the function module or the basic device.
- after loading the Lenze setting.
3)
Frequency input alternatively 0 ... 10 kHz single-track or 0 ... 1 kHz two-track, config. via C0425
52
Function
(Lenze setting: bold print)
Output frequency
GND1,
Reference potential for analog signals
Input for actual value or setpoint
Switch over the range with the DIP switch and in C0034:
Voltage signal
Current signal
Internal, stabilised DC voltage source for the
setpoint potentiometer
Internal DC voltage supply for control of digital
inputs and outputs
Controller inhibit (CINH)
Activation of JOG frequencies
JOG1 = 20 Hz
JOG2 = 30 Hz
JOG3 = 40 Hz
DC-injection brake (DCB)
Change of direction of rotation
CW/CCW rotation
GND2,
Reference potential for digital signals
Ready for operation
internal supply:
external supply:
DC supply for X3/A1
internal (bridge to X3/20):
external:
Level
(Lenze setting: bold print)
0 ... +6 V
0 ... +10 V
1)
-
0 ... +5 V
0 ... +10 V
-10 ... +10 V
2)
0 ... +20 mA
+4 ... +20 mA
+4 ... +20 mA (open-circuit
monitored)
+5.2 V
+20 V ±10 % (ref.: X3/7)
1 = enable
e1
JOG1
1
JOG2
0
JOG3
1
1 = DCB
E4
CW
0
CCW
1
-
0 ... +20 V
0 ... +24 V
+20 V
+24 V
EDK82ZMFBC-001 DE/EN/FR 7.0
E2
0
1
1