USER'S MANUAL. PROLITE-75
To access the LOGGER function:
1.-
From the GPON METER function press the soft key LOGGER [F5].
The data stored in a logger is:
-
Power at 1310, 1490 and 1550 nm (dB).
-
Status Message regarding power level (LOW, GOOD, HIGH).
-
Date and Time of acquisition.
-
Average level power for each wavelengths.
-
Relative level power for each wavelengths.
-
Threshold group used.
The PROLITE-75 allows you to store up to 100 acquisitions or loggers. These
measures are stored on its memory for later view, printing or transfer to a PC.
The LOGGER main screen shows a list with all loggers stored until now. On the
left side of the logger line it indicates the logger number, followed by date and time of
acquisition. When saving a logger, system assigns automatically a registration number
to the new file, which is correlated to the numbering in the list of loggers. It can also
reuse a number from a logger that was removed.
To select a logger, you should press the arrow keys
points at the desired logger.
If there are not loggers stored, it is displayed the message "EMPTY LOGGER".
At the bottom of the screen, the soft keys provide access to the next options:
BACK [F1]:
04-2009
Figure 13.- List of stored loggers.
Returns to the GPON METER screen (see section
4.2.2).
[11] until the cursor
Page 23