Télécharger Imprimer la page

Promax PROLITE-75 Mode D'emploi page 61

Publicité

Les langues disponibles

Les langues disponibles

USER'S MANUAL. PROLITE-75
1490 nm [F4]:
1550 nm [F5]:
4.2.2.4
THRESHOLD function
The THRESHOLD function allows you to edit the threshold values that will be
used during measurement.
To access the THRESHOLD function:
1.-
From the GPON METER function press the soft key THRESHOLD [F4].
The THRESHOLD function allows you to define a minimum threshold value
(LOW) and maximum (HIGH) of acceptability for each wavelength (Fig. 12.-).
Once defined, they appear in the graph at the GPON METER function, in the
shape of a line with an "x" in the middle (--x--) (Fig.- 7.-).
Status level defined by the threshold values are:
-
Power level above the maximum threshold value is equal to HIGH.
-
Power level between the maximum and minimum threshold value is equal to
GOOD.
-
Power level below the minimum threshold value is equal to LOW.
In addition, LEDs associated with the ONT and OLT signals [5] change its colour
depending on the power signal level.
-
If level is LOW, the colour of the LED is RED.
-
If the level is MEDIUM, the colour of the LED is GREEN.
-
If the level is HIGH, the colour of the LED is ORANGE.
04-2009
It captures the reference power at 1490 nm. Once
captured, confirm the value pressing the key
It captures the reference power at 1550 nm. Once
captured, confirm the value pressing the key
[12].
[12].
Page 21

Publicité

loading