6.1.8.
fixing the solenoid
The solenoid is fixed to the valve housing with 4 cap screws.
Fig. 1:
Fixing the solenoid
Cap screws
6.1.9.
model with a terminal box
DANGER!
risk of explosion!
Only permanently laid cables and wiring may be inserted
The operator must provide suitable stress relief.
Wires with an outside diameter of 6 to 13 mm may be used.
Observe the maximum thermal loading of the cables or wires to
be inserted.
The inserted break-off seal must be matched to the diameter of
the cable or wire.
The rated cross-section of the cable or wire strands must be at
least 0.75 mm² and may not exceed 2.5 mm².
The screws for fixing the cover of the terminal box must be tigh-
tened with a torque of 100 Ncm (± 5 %).
The solenoid coils may also be executed with a terminal box, with or
without fuse/contactor (to separate Design Type Inspection Certi-
ficate) as desired.
For protection against inadvertent opening of the cover, the latter
bears the marking:
Open only when the voltage is switched off!