For a transmitter to be used, the module first has to self-learn its code. The memorise procedure is illustrated below, the module
can memorise up to 64 different codes.
Memorising a new transmitter by activating the P.P. function
- Press the PGM button once for 1sec and the DL1 LED will start blinking at 1 sec intervals.
- Press the transmitter button within 10 sec to memorise with the P.P. (Step-by-step) function
To exit the programming procedure wait 10 sec or press the PGM button for 1 sec, the DL1 LED will return to normal blinking at
3 sec intervals.
Cancelling all transmitters from the memory
- Keep the PGM button pressed for 15 sec, the DL1 LED will start blinking rapidly and when it goes out the memory has been
erased.
- Release the PGM button, the memory has been cancelled and the DL1 LED will return to normal blinking at 3 sec intervals.
N.B.:
The transmitters are stored on an EPROM (U7) memory board that can be removed and installed in a new control unit in case of
breakdown.
For safety reasons, transmitters cannot be memorised during the open/close cycles of the motor.
When entering the memorise transmitter procedure, if the DL1 LED gives a prolonged blink and then goes out, this signals that the
receiver memory is full and no other transmitters can be memorised or that the transmitter is not compatible.