5) Adjust the closing limit switch cam, the SWC LED turns off.
If braking is required in the closing phase, the limit switch triggering should be anticipated.
6) Cut off power supply.
7) Move the door half-way and lock it again.
8) Reset power supply. The STOP, PHOT, SWO and SWC LED's should light up.
9) Give a step-by-step control signal by pressing the appropriate button or using the remote control.
10) The door should move in the opening phase. In the negative, it is sufficient to invert the speed wires (6<>8) of the motor and
the limit switch inputs (SWO<>SWC).
11) Adjust Time and Operating and Motor power logic.
If braking is required, move DIP3 to ON and adjust the braking time of trimmer TSLOW.
WARNING! This adjustment affects the safety level of the automatic system.
Check that the thrust applied onto the wing complies with regulations in force.
On the power supply transformer, a Faston connector (T1) is provided which allows to adjust motor power to 4 different levels. By
positioning the Faston (T1) on 120, the minimum power is obtained, by moving the Faston to 210 the maximum power is obtained.
TCA
It allows to adjust the automatic closure time. Check Dip-Switch N°1= On.
The adjustment varies from 1s minimum to 90s maximum
TSLOW With Dip-Switch 3 On, it adjusts the slowdown cycle time from 1 to 12 secs.
With Dip-Switch 3 Off, it adjusts the work time from 10 to 120 secs. In this case the slowdown option is disabled.
DIP 1
"TCA"
The automatic closure is enabled or disabled
Off: disabled automatic closure
On: enabled automatic closure
DIP 2
"Prelam."
Forewarning flashing light enabled or disabled
Off: disabled forewarning flashing light
On: enabled forewarning flashing light. The flashing light is activated 3 s before the starting of the motor.
DIP 3
"Rall."
Enables or disables the slowdown cycle.
Off: Slowdown disabled. The TSLOW trimmer adjusts the motor work time from 10 to 120 secs.
Set a work time longer than the duration of an operation.
On: Braking in both opening and closing phases.
N.B.: the braking phase starts when the limit switches are triggered.
By using trimmer "TSLOW", preset a braking time slightly higher than the time required to complete the
operation.
DIP 4
"P.P. Mod" The operating mode of "P.P. Push button" and of the transmitter are selected.
Off: Operation: OPEN > STOP > CLOSE > STOP >
On: Operation : OPEN > CLOSE > OPEN >
DIP 5
"PHOT. AP." The photocells in the opening phase are enabled or disabled.
Off: enabled photocells in the opening phase.
On: disabled photocells in the opening phase.
DIP 6
"Cond."
The multi-flat function is enabled or disabled.
Off: disabled multi-flat function.
On: enabled multi-flat function. The P.P. (Step-by-step) impulse or the impulse of the transmitter have no
effect in the opening phase.
DIP 7
"Spunto"
The motor start pickup is enabled or disabled.
Off: disabled pickup.
On: enabled pickup. At the beginning of each operation the maximum torque of the motor is for approx. 2s.
DIP 8
"Radio"
Only for "RI" versions. Enables or disables transmitters with programmable codes
On: Radio receiver enabled exclusively for rolling-code transmitters.
Off: Receiver enabled for both rolling-code and programmable transmitters (self-learn and dip-switch) .
The control system has a series of self-diagnostics LED's which allow to check all functions:
SW1 LED
It switches off when the SWO opening limit switch is triggered
SW2 LED
It switches off when the SWC closing limit switch is triggered
STOP LED
It switches off when the STOP push button is pressed
PHOT LED
It switches off when the photocells are not aligned or if obstacles are present
OPN LED
It switches on when the OPEN push button is pressed
CLS LED
It switches on when the CLOSE push button is pressed
PP LED
It switches on when the PP push button is pressed
PGM LED
It flashes to show the correct operation of the control unit.
5 quick flashes, followed by a pause, of LED PGM indicate the activation of the safety edge.
The control unit is fitted with a built-in radio module for receiving remote controls both with fixed codes and variable codes (see
dip-switch 8 functions), with a frequency of 433.92MHz.
8
TO ADJUST THE MOTOR POWER
FUNCTIONS OF THE TRIMMERS
DIP-SWITCH FUNCTIONS
CONFIGURATION WITH BUILT-IN RECEIVER (ONLY "RI" VERSIONS)
LED DIAGNOSTICS