correctly programmed, the DL2 LED (green) will flash once.
4 - The code programming time resets automatically so that you can programme the next remote control.
5 - To finish programming, let 10 seconds pass and then press the PROG. button briefly. The red DL1 LED will stop flashing.
6 - Reposition DIP 1 to OFF and DIP 2 to OFF.
7 - You have completed the procedure
PrOCEDUrE fOr DELETING ALL rADIO CODEs UsED ONLY fOr COMPLETE OPENING
You can only delete the codes if the gate is closed.
1 - Position DIP 1 to ON and then DIP 2 to ON.
2 - The red programming DL1 LED will flash ON and OFF, one second on each, for 10 seconds.
3 - Press and hold the PROG button for 5 seconds. The green DL2 LED will flash twice to confirm that the stored codes
have been deleted.
4 - The red programming DL1 LED remains active and you can programme new codes as shown above if required.
5 - Reposition DIP 1 to OFF and DIP 2 to OFF.
6 - You have completed the procedure.
HOW TO CHECK If THE MEMOrY Is fULL fOr rADIO CODEs UsED ONLY fOr COMPLETE OPENING
You can only check the memory if the gate is closed.
1 - Position DIP 1 to ON and then DIP 2 to ON.
2 - The green DL2 LED will flash 6 times if the memory is full (64 codes have been stored).
3 - After this, the DL1 programming LED will remain active for 10 seconds, so that you can delete all codes if required.
4 - Reposition DIP 1 to OFF and DIP 2 to OFF.
5 - You have completed the procedure
POINT H
- PrOGrAMMING rADIO CODEs fOr PEDEsTrIAN OPENING
(UP TO 62 CODEs - ONLY fOr CrX MODELs)
You can only programme the codes if the gate is closed.
1 - Position DIP 1 to ON and then DIP 3 to ON.
2 - The red programming DL1 LED will flash ON and OFF, one second on each, for 10 seconds.
3 - Press the remote control button (normally channel B) within the 10 seconds proscribed. If the remote control has been
correctly programmed, the DL2 LED (green) will flash once.
4 - The code programming time resets automatically so that you can programme the next remote control.
5 - To finish programming, let 10 seconds pass and then press the PROG. button briefly. The red DL1 LED will stop flashing.
6 - Reposition DIP 1 to OFF and DIP 3 to OFF.
N.B: If THE DL1 LED CONTINUEs TO fLAsH rAPIDLY, THIs MEANs THAT DIP 1 Is sTILL POsITIONED TO ON
AND ANY MANOEUVrE HAs BEEN DELETED.
7 - You have completed the procedure.
PrOCEDUrE fOr DELETING ALL rADIO CODEs UsED ONLY fOr COMPLETE OPENING
You can only delete the codes if the gate is closed.
1 - Position DIP 1 to ON and then DIP 3 to ON.
2 - The red programming DL1 LED will flash ON and OFF, one second on each, for 10 seconds.
3 - Press and hold the PROG button for 5 seconds. The green DL2 LED will flash twice to confirm that the stored codes
have been deleted.
4 - The red programming DL1 LED remains active and you can programme new codes as shown above if required.
5 - Reposition DIP 1 to OFF and DIP 3 to OFF.
6 - You have completed the procedure.
HOW TO CHECK If THE MEMOrY Is fULL fOr rADIO CODEs UsED ONLY fOr COMPLETE OPENING
You can only check the memory if the gate is closed.
1 - Position DIP 1 to ON and then DIP 3 to ON.
2 - The green DL2 LED will flash 6 times if the memory is full (64 codes have been stored).
3 - After this, the DL1 programming LED will remain active for 10 seconds, so that you can delete all codes if required.
4 - Reposition DIP 1 to OFF and DIP 3 to OFF.
5 - You have completed the procedure.
f
UNCTIONING Of CONTrOL ACCEssOrIEs
ATTENTION: ONLY IMPULsIVE COMMANDs HAVE TO BE CONNECTED.
Make sure that any other type of command accessories (e.g. mass detectors) used on the installation are set
in the IMPULsIVE mode, otherwise, the gate will be operated even without the protection of the safety devices.
sTEP BY sTEP or AUTOMATIC commands
(K BUTT button, PED BUTT button, RADIO REMOTE button)
DIP 6 - Off
The K BUTT, the PED BUTT button, the RADIO REMOTE buttons perform the cyclic command open-
stop-close-open-stop-etc.
DIP 6 - ON
The K BUTT, the PED BUTT button, the RADIO REMOTE buttons perform:
- the open command, if pressed with the gate completely closed
- the close command, if pressed with the gate completely opened
- no effect, if pressed during the gate opening
- the gate re-open, if pressed while the gate is closing
The K BUTT opens the gate completely, whereas the PED BUTT opens the gate partially as described in Point F.
CLOCK fUNCTION
If you want the Clock function must request T2 with firmware 08.
ATTENTION: A CLOCK CONNECTED TO T2 with fw 09 or more ACTIVATEs THE AUTOMATIC MOVEMENT Of
THE GATE WITHOUT HAVING THE PrOTECTION Of THE sAfETY DEVICEs!
The Clock Function is useful during rush hours, when traffic is heavy and the flow is slow (e.g. entrance/exit of employees,
emergencies in residential areas or car parks and, temporarily, for removal vans) and it's necessary to keep the gate opened.
CLOCK fUNCTION APPLICATION
It is necessary to request a T2 control panel with firmware 08.
select the automatic functioning DIP 6 Off.
It can be done by connecting a switch and/or a daily/weekly clock either in parallel to the K BUTT button or instead of the K
BUTT button. When the control board receives this command, the gate will open and by keeping this contact closed for all
the time of the gate opening, the Clock Function is automatically activated. In fact, once reached the open position, the gate
will remain opened and all of the control board functions are blocked. Only when K BUTT contact is released, the control
board functions are re-activated and the Automatic Closing restarts (if enabled) doing the countdown to the gate closing.
PEDEsTrIAN command (PED BUTT - COM)
This command is useful to open the gate partially, just enough, for example, to permit a pedestrian crossing. In fact, the
Pedestrian command (see Point F) is carried out only by opening the motor M1 just enough for a pedestrian to pass, as
described into the Point F procedure. From the Pedestrian opening position the Automatic Closing can be enabled or
disabled with DIP3. From the Pedestrian opening position, the gate can be completely opened by the OPEN or by the K
BUTT button or by the RADIO button.
AUTOMATIC CLOsING (from the COMPLETE open position)
The Automatic Closing from the complete open position can be enabled turning ON the DIP3.
The maximum gap of time that can be programmed is 5 minutes (see Point D and E).
AUTOMATIC CLOsING (from the PEDEsTrIAN open position)
The Automatic Closing from the pedestrian open position can be enabled turning ON the DIP3. The maximum gap of time
that can be programmed is 5 minutes (see Point F).
ELECTrIC LOCK (LOCK A+) command
The DIP 8 in the ON position enables the Electric Lock (MAX 15W 12V) command. The Electric Lock (LOCK A+) will be
automatically turned ON each time the gate opens. If the DIP8 is OFF, the Electric Lock command is DISABLED.
The Electric Lock remains active for 1,5 seconds.
MANUAL rELEAsE fACILITY
The DIP 9 in the ON position enables the Manual Release Facility. Once the gate has completely closed, a short reversal
manoeuvre (0.2 seconds) will be done to ease manual release.
ELECTrIC LOCK unlocking fACILITY
The DIP 9 in the ON position enables the Electric Lock unlocking Facility. From close position, just before opening, the gate
will perform a short closing manoeuvre (0.5 seconds) to ease unlocking from electric lock.
ELECTrIC LOCK coupling fACILITY
The DIP 10 in the ON position enables the Electric Lock coupling Facility. Once the gate has closed, a short hammering
close pulse (0.5 seconds) will be done at full power to guarantee the electric lock or mechanical bolt coupling.
f
UNCTIONING Of sAfETY ACCEssOrIEs
PHOTOCELL (PHOT - COM)
In case the switch DIP4 is in the OFF position, the photocells are active both in gate opening and in gate closing. In this
configuration, if an obstacle cuts the photocell beam:
- while the gate is closing, the gate will open
- while the gate is opening, the gate will stop and will restart opening when the obstacle is removed
- while the gate is still, it will not move neither in opening nor in closing.
In case of the switch DIP4 is in the ON position, the photocells are active only in gate closing.
In this configuration, if an obstacle cuts the photocell beam:
- while the gate is closing, the gate will open
- while the gate is opening, the gate will continue open
- while the gate is still, it will open if a open command is request, it will remain still if a close command is request.
The photocell input (PHOT - COM) is a NORMALLY CLOSED contact.
In case there are more couple of photocells, the contacts from all the photocell receivers must be connected in series. In
case the photocells are not installed, this contact must be short circuited with a wire
jump (from PHOT to COM) to permit the gate to operate.
ATTENTION: In case the receiver led remains lit, malfunctioning of the main
supply is suspected. It is advisable to connect electrically to earth the columns
or the photocells stands to the terminal D-, to shield the photocells from external
noise. Be careful not to short circuit the system when the supply phases are
inverted!
AUTOMATIC CLOsING AfTEr THE TrANsIT THrOUGH THE PHOTOCELL
This option could be useful to close automatically the gate when the vehicle left and disengaged the photocell beam. If the
DIP12 is turned ON, this function is activated and the PHOTO input will have two purposes:
- detect the obstacle and prevent the gate movement in according with the DIP4 position;
- close the gate as soon as the vehicle leaves the photocell beam.
If DIP12 ON and DIP4 Off
If the gate is opening and a vehicle crosses the photo beam, the gate will stop. When the vehicle leaves, the gate will close
automatically after 1 second pause.
If DIP12 ON and DIP4 ON
If the gate is opening and a vehicle crosses the photo beam, the gate will continue to open. When the vehicle leaves, the
gate will stop and then closes automatically after 1 second pause.
If the complete gate open position is reached before the vehicle leaving, the DIP12 will be ignored and the automatic
closing will be managed in according to the DIP3 position.
If during closure there is as fast transit (example pedestrian), the gate opens for 2 seconds and then re-close.
PAY ATTENTION: it is highly recommended to check photocells operation at least every 6 months.
sAfETY sTrIP (EDGE - COM)
If an obstacle presses the safety strip:
- while the gate is still, it will not move neither in opening nor in closing
- while the gate is closing, the gate will open
- while the gate is opening, the gate will close.
In case the safety strip is held pressed a further quick reversion, after 2 seconds, is performed. The gate interrupts any
movement and this alarm state is indicated by 1 minute Blinker flashing. The normal gate operations can be restored by
pressing any push button or radio commands.
12Vdc