ONNECTION IN BUILT HEATEr PrOBE ON THE KING ICE
O
N BOArD HEATEr sYsTEM
The KING ICE motor is arranged to be connected through Plug A to a thermal probe to check the external temperature.
Carry out the connection between J7 on the T2 pc board and the plug A on the KING ICE motor as explained in the
drawing.
For the connection, use a two-wire cable with a minimum diametre of 1 mm
connected to the PROBE. Maximum distance motor with PROBE to T2 control panel: 10 m.
The probe for motor heating is a device intended to be used in extremely cold environment (up to -30°C) to avoid motor
freezing. Such device activates automatically when the gate is steady (the position being irrelevant, provided it is not
moving). The work of the heater is indicated by both the DL6 and DL7 leds for the motor number 1, and by the DL4
and DL5 leds for the motor number 2.
F2 5A
Motor protection fuse
POINT C
- MOTOr rOTATION DIrECTION CHECK
1 - Unlock the operators with the Manual Release - swing open the leaves about halfway and lock again the operators.
2 - Turn DIP1 to ON position The red LED DL1 starts blinking.
3 - Press the PROG button and hold it - When GREEN LEDS DL3 and DL5 are on, the gate leaves are opening (with a phase
shift of 2 seconds). Check the leaves swinging and the opening mechanical stopper position (movement is now performed
in "man present" mode, open-close-open-etc.). If any of the leaf closes instead of opening, release PROG button, turn off
the main power and reverse the two phase wires (V1/2 and W1/2) of the relevant motor/s.
4 - Press the PROG button and hold it to CLOSE completely the gate. When RED LEDS DL4 and DL6 are on, the gate
leaves are closing (with a phase shift of 4 seconds). Check leaves swinging and the closing mechanical stopper position.
5 - After 3 seconds motor starting and for the next 10 seconds motor working, the torque controls automatically activated.
Set the motor torque by the TORQUE Trimmer/s which varies the output voltage to the motor/s (turn clockwise to
increase the torque).
6 - After other 10 seconds motor working, the low speed controls automatically activated (DIP7 ON). Set the motor low speed
by the LOW SPEED Trimmer to select the gate leaf low speed in approaching.
7 - Close completely the gate.
8 - Turn DIP1 to OFF position, LED DL1 turns off.
During Point C procedure, safety devices (photocells and safetystrip) are not active and the remote control cannot
operate.
(#) In Point D, Point E and Point F procedures, all the safety devices (photocells and safety strip) will be active, so they
must be properly installed and connected to the control board. Any changing of the safety devices input state, will stop
the Point D, Point E or Point F procedure that must be repeated from the beginning.
POINT D
- PrOGrAMMING fOr 2 MOTOrs (#)
1 - The gate must be fully closed.
2 - Turn DIP2 to ON position, LED DL1 starts blinking
3 - Press PrOG. Button, motor M1 opens.
4 - Once reached the open position, let 1 second pass and press the PrOG button to cut out motor M1 (time travel of M1
has now been just stored with this operation).
5 - Motor M2 opens, automatically.
6 - Once reached the open position, let 1 second pass and press the PrOG button to cut out motor M2 (time travel of M2
has now been just stored with this operation).The gap of time between now (stop of motor M2) and the next pressing of
the PROG. button (see step 7 below) will be then stored as waiting time for Automatic Closing feature.
7 - Press PrOG. button, M2 closes and the Automatic Closing time is stored (see DIP3 function to enable or disable the
Automatic Closing feature). The gap of time between now (close of motor M2) and the next pressing of the PROG. button
(see step 8 below) will be stored as time delay between motor M2 and motor M1 closing, during normal operations.
8 - Press the PrOG. button, motor M1 closes thus setting the delay time between M2 and M1, as explained in step 7 above.
9 - The LED DL1 will turn OFF, signalling exit from the Point D procedure. Closing of the gate will be carried out at normal
A
PLUG
fOr CONNECTION Of
THErMAL PrOBE
1
to be connected to the terminal block J7 on
the T2 pc board
2
available
3
to be connected to the terminal block J7 on
the T2 pc board
free
When the motor is running the heating system is inoperative.
On elapsing of 10 seconds delay from gate stop, the heating system gets activated (in case the environment
temperature in the motor area is below 10°C).
2
. KING ICE has a 1 m cable already
Upon achieving a 20°C temperature the heating system deactivates, maintaining a constant environment temperature.
TECHNICAL DATA
Operation voltage
Resistance
Working temperature
10 - Turn DIP2 to Off position.
During Point D procedure, the safety devices (photocells and safety strip) are active.
POINT E
ATTENTION: in order to manage one motor only, OPEN JUMPEr JP17.
1 - The gate must be fully closed.
2 - Turn DIP2 to ON position, the LED DL1 starts blinking
3 - Press PrOG. button, the motor M1 opens.
4 - Once reached the open position, let 1 second pass and press the PrOG button to cut out motor M1 (time travel of M1
5 - Press PrOG. button, M1 closes and the Automatic Closing time is stored (see DIP3 function to enable or disable the
6 - The LED DL1 will turn OFF, indicating exit from the Point E procedure. Closing of the gate will be carried out at normal
7 - Turn DIP2 to Off position.
During Point E procedure, the safety devices (photocells and safety strip) are active.
POINT f
1 - The gate must be fully closed.
2 - Turn DIP2 to ON position, the LED DL1 starts blinking quickly.
3 - Immediately, turn also DIP1 to ON position, the LED DL1 starts blinking slowly.
4 - Press the pedestrian pushbutton PED. BUTT, motor M1 opens
5 - When the motor M1 leaf is opened enough for the pedestrian crossing, press the pedestrian pushbutton to stop the
6 - Press the pedestrian pushbutton PED. BUTT, M1 closes and the Pedestrian Automatic Closing time is stored (see
7 - Turn DIP1 to Off position.
8 - Turn DIP2 to Off position.
During Point F procedure, the safety devices (photocells and safety strip) are active.
POINT G
(UP TO 62 CODEs - ONLY fOr CrX MODELs)
You can only programme the codes if the gate is closed.
1 - Position DIP 1 to ON and then DIP 2 to ON.
2 - The red programming DL1 LED will flash ON and OFF, one second on each, for 10 seconds.
3 - Press the remote control button (normally channel A) within the 10 seconds proscribed. If the remote control has been
31
31
5Vdc
10K ±2% (at 25°C)
-30 ÷ +55°C
speed and only on approaching total closing at low speed (depending on the adjustment of LOW SPEED trimmer).
- PrOGrAMMING fOr 1 MOTOr (M1) (#)
has now been just stored with this operation). The gap of time between now (stop of motor M1) and the next pressing of
the PROG. button (see step 5 below) will be then stored as waiting time for Automatic Closing feature.
Automatic Closing feature).
speed and only on approaching total closing at low speed (depending on the adjustment of LOW SPEED trimmer).
- PrOGrAMMING Of PEDEsTrIAN OPENING (#)
travel (thus defining the opening stroke of motor M1). The gap of time between now (stop of motor M1) and the next
pressing of the PROG. button (see point 6 below) will be stored as waiting time for Pedestrian Automatic Closing feature.
DIP3 function to enable or disable the Automatic Closing feature).
- PrOGrAMMING rADIO CODEs fOr COMPLETE OPENING
B
PLUG
fOr CONNECTION Of
MOTOr
1 -> V
2 -> W
3 -> U
>-
G
B