Dometic 10 Série Notice D'utilisation page 33

Masquer les pouces Voir aussi pour 10 Série:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

RMD10
WARNING type fault messages
All faults of the WARNING type are reset automatically once the fault has been
rectified.
RMD10.5,
RMD10.5T,
RMD10.5X,
RMD10.5XT
RMD10.5S,
RMD10.5XS:
W01
W05
W06
W11
W10
+ beep
ERROR type fault messages
All faults of the ERROR type must be reset manually:
➤ RMD10.5T, RMD10.5XT: Press the control knob for 2 seconds.
➤ RMD10.5, RMD10.5X, RMD10.5S, RMD10.5XS: Press
✔ A beep sounds.
✔ The error has been reset.
EN
Fault
Defective temperature
sensor in the refrigerator
compartment
AC power not connected or
AC voltage < 190 V
DC power not connected
DC overvoltage (> 16 V)
Tank stop mode: Gas opera-
tion is blocked for
15 minutes.
Beep
The door is opened for more
than 2 minutes.
Troubleshooting
Solution
Contact an authorized customer
service.
Connect the refrigerator to AC or
select a different energy type, e.g.
gas or DC.
Connect the refrigerator to DC or
select a different energy type, e.g.
gas or AC.
Reduce the DC supply voltage.
Wait 15 minutes or switch to another
operating mode.
Close the door.
for 2 seconds.
33

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

Rmd10.5Rmd10.5tRmd10.5xtRmd10.5sRmd10.5xsRmd10.5x

Table des Matières