Télécharger Imprimer la page

Kospel SE140 Mode D'emploi page 21

Publicité

Les langues disponibles

Les langues disponibles

Start-up
Check out the pipe connections and make sure that you observe the connection diagrams
before start-up.
Cylinder filling:
turn on the valve on cold water supply pipe,
turn on the hot water outlet valve (water outflow without the air bubbles indicates
that the storage is full)
turn off the outlet valves,
Check for water leaks.
Check out the safety valve performance in accordance to valve manufacturer's instruction.
Operation
Check out the safety valve performance once every 14 days. Do not use the cylinder
if the water does not come out (it indicates that the valve is broken).
Clean inside of the cylinder periodically. The frequency of cleaning depend on the
degree of water hardness. The cleaning should be done by a qualified person.
The wear condition of the anode must be inspected annually.
The anode must be replaced once every 18 months.
-
anode rod replacement [10] (SE Cylinder – 140,250,300,400 litres): take off the
upper lid [11], take out an insulation ring, turn off the cut-off valve on cold water
supply pipe, turn on the hot water valve (mixer tap), turn the drain valve on ,drain
as much water as you can easily screw out the anode rod (avoiding room flooding)
screw off the cork and screw out the anode rod,
-
anode rod replacement [10] (SE Cylinder -200 litres): take off the upper lid [11], take
out an insulation ring, turn off the cut-off valve on cold water supply pipe, turn on
the hot water (mixer tap), turn the drain valve on, drain as much water as you can
easily screw out the anode rod (avoiding room flooding), take off the access hole
cover [13] and screw out the anode rod.
Heat up the water above 70°C periodically for hygiene reasons.
Failures or malfunctions notify to the seller.
Insulate the outlet pipe to minimise the heat loss (recommended).
Above activities are beyond of the scope of warranty service (should be done by user).
PL;EN;DE;FR-042_f.1299
EN
21

Publicité

loading

Ce manuel est également adapté pour:

Se200Se250Se300Se400Se500Se