The minimum proximity of objects, property, persons and/or animals to be kept in front of the air distribution area must
be at least 1,5 m, having checked that they can support the maximum temperature, which can be found by adding the
room temperature + ΔT @ 1.5 m (as shown on the identification label affixed to the space heater itself).
5.2. POWER CONNECTIONS
5.2.1 Connection to the mains supply
Warning
The power line must be earthed and fitted with a residual current circuit breaker.
The power cable must be connected to a panel fitted with a cut-out.
Before switching on the heater and, therefore, before plugging it into the electrical power supply, check that the power
supply specifications are the same as those stated on the identification plate.
Warning
The heater is fitted with a temporary power cable, used for the working test.
Warning
The temporary power cable must be removed and replaced with a H07RN-F cable having a section of at least
1.5 mm
2
: a larger section is required if the cable is more than 25 metres long.
The cable must be stripped, leaving the earth lead at least 2 cm longer.
The electrical power cable must be connected in conformity to the polarity specified on the main terminal board of the
electrical panel: phase (L) and neutral (N).
Warning
If polarities L and N are incorrect, the space heater may stop a few seconds after it is switched on for the first
time.
5.2.2 Connection to the room thermostat
If any room thermostat or other accessories are connected to the system (such as the timer for example) this must be
done by connecting the electrical cable to the thermostat plug (H):
• Remove the plug (H) from the electrical switch panel. Remove the external cover and
• extract the internal connector;
• Connect the ON-OFF contact for the room thermostat (or other accessory) with an electrical cable, with a maximum
length of 15 m, to terminals 1 and 2 of the connector .
• Reassemble the plug (H) and plug it back into the panel socket.
L-L 304.00-BM
EN
• Remove the jumper between terminals 1 and 2 of the plug