Fig. 36: Spoiler adapter on the clamp, self-centering not functioning
4.4

Clamps, self-centering 1 987 009 A09N

Scope of supply:
- 4 x clamps
- 8 x gripper arms A)
Installation: (see Figs. 37and 38)
- The gripper arms A) are passed into the respective guide B)
and fixed with the screws C).
A
C
Fig. 37: Installation of gripper arm
- Loosen the screws C) to adapt the gripper arms to the tire size.
- This is unlocked by removing the locking screws D). The
adapter is set to match the diameter of the rim lip by turning. The
locking screw is fixed in place again by pressing it in once the
adapter has been set.
- The clamp is attached firmly to the wheel with the locking screw
E).
Fig. 38: Clamp, self-centering
1 689 978 435N
08.12.08
B
4.5

Calibration stand 1 987 009 A10N

Scope of supply:
- 1 x calibration frame A) (Fig. 39)
- 3 x feet B) (Fig. 39)
- 2 x spirit levels C) (Fig. 39)
- 2 x adapters D) (Fig. 39)
Installation:
- Carefully remove the calibration frame A) (Fig. 39) from the
carton and lay it on a firm and flat surface.
B)
A)
E)
B)
Fig. 39: Calibration frame in the packing
- Remove the cover E) (Fig. 39) of the compartment for small
parts in the middle of the calibration frame and remove the spirit
level included with it.
Avoid severe vibration and external mechanical effects
on the calibration frame and the attached, fixed spirit
levels. Measuring instruments need to be handled with
care.
- Remove the feet from the holders on the upper side. Carefully
turn the calibration frame over. Screw in the feet into the
threaded holes provided on the underside.
use the calibration frame on a firm and level surface to
avoid incorrect measurements.
- Align the frame by rotating the feet and with the air of the built-
in spirit level C) (Fig. 39). Hold the settings by using the locknut
and set the calibration frame up on a firm surface.
Fig. 40: Calibration frame set up
C)
D)
31