3.1 Technical Data
Ambient temperature
Relative humidity
Tab. 1
Storage in a closed environment, ambient temperature
Ambient temperature for transport
Relative humidity
Tab. 2
Supply voltage
Max. welding current
Max. gas pressure
Wire feed rate
Standard roll diameter
Drive
Protection type
Weight
* The tolerances depend on the selected speed and the activation selected in each case.
Tab. 3
Nominal voltage
Idle speed
Starting torque
Average idle current
Tab. 4
Max. continuous current
Max. continuous three-phase current
Max. angular acceleration
Tab. 5
WARNING
Operating Safety] 1203).
Ambient conditions during operation
Ambient conditions for shipment and storage
General
Measured motor values
Max. recommended motor values
- 10 °C to + 40 °C
up to 90 % at 20 °C
- 10 °C to + 40 °C
- 10 °C to + 55 °C
up 90 % at 20 °C
see Tab. 4, 7, 8
Max. 500 A at 100% duty cycle
0,5 MPa (5bar)
i= 15/1 v= 0-20 m/min, i= 30/1 v= 0-10 m/min*
20 mm
Four rolls
IP23
approx. 2.9 kg
32 V
5900 rpm
756 mNm (107 oz-in)
80 mA
2,3 A
115 mNm (16.3 oz-in)
64 10³rad/s²