Télécharger Imprimer la page

Circuits With Ig Wiring - Cristec RCE/100-1E-2IG Manuel Utilisateur

Masquer les pouces Voir aussi pour RCE/100-1E-2IG:

Publicité

Les langues disponibles

Les langues disponibles

4.4.3
C
IRCUITS WITH
The IG connection can be used to start regulated alternators (or some solar panel or wind turbine regulators).
These alternators must be excited with an excitation voltage on one of their terminals.
In this case the IG terminal must be connected to the battery voltage coming from the ignition key.
If the voltage source is solar or wind, or other, the IG terminal must be connected to the positive pole of a battery
through a switch.
IT IS IMPERATIVE TO CONNECT THE BAT-
TERMINAL OF THE RCE TO THE COMMON
NEGATIVE BATTERY BANK.
.
Tout manquement détériorera les composants
du répartiteur et provoquera sa dégradation.
IG
WIRING
fuse
RCE
Isolator
Starter
batteries
Alternator
fuse
Circuit
breaker
House
batteries
To
consummers
fuse
Circuit
breaker
Bow thruster
batteries
fuse
Circuit
breaker
25