Malfunction
No coating material
emerges from the
nozzle
Atomisation too coarse
Spray jet pulsates
Coating material causes
"paint tears"
Too much fog of
coating material
(Overspray)
Paint in the ventilating
hose
Device does not
function
If the supply cord of this appliance is damaged, it
must only be replaced by a repair shop appointed by
the manufacturer, because special purpose tools are
required.
Warning: Do not connect the blue or brown wire to the
earth terminal of the plug! The wires in this mains lead
are coloured in accordance with the following code:
blue = neutral brown = live
As the colours of the wires in the mains lead of this
appliance may not correspond with the coloured
markings identifiying the terminals in your plug,
proceed as follows:
Cause
Nozzle clogged
Material volume setting turned too far
to the left (-)
No pressure build-up in container
Container empty
Feed tube loose
Feed tube clogged
Material volume too large
Material volume adjusting screw turned
too far to the right (+)
Nozzle contaminated
Viscosity of coating material too high
Too little pressure build-up in container
Air filter heavily soiled
Amount of air too low
Coating material in container running
out
Nozzle seal worn
Air filter heavily soiled
Too much coating material applied.
Distance to the object too large
Too much coating material applied
Amount of air too high
Diaphragm soiled
Diaphragm defective
Device overheated
Warning
Remedy
Clean
Turn to the right (+)
Tighten container
Refill
Insert
Clean
Turn material volume adjusting
screw to the left (-)
Clean
Add 5 - 10% dilution
Tighten container
Change
Turn the air volume control to
the right (+)
Refill
Replace
Change
Turn material volume adjusting
screw to the left (-)
Reduce distance
Turn material volume adjusting
screw to the left (-)
Turn the air volume control to
the left (-)
Clean the diaphragm
Replace the diaphragm
Unplug the power plug, let
the device cool down approx.
30 minutes, do not bend the
hose, check the air filter, do not
cover the intake slots
GB
23

Publicité