The number of cells at the lower right of the display is flashing. Set the number of the cells with
the buttons "INC" and "DEC". Keep the respective button pressed for quick adjustment. The
associated rechargeable battery nominal voltage is automatically calculated and displayed to
the left of the cell number.
Confirm the number of the cells by pressing the "START/ENTER" button.
• When no display is flashing anymore, start charging by keeping the "START/ENTER" button
pushed (approx. 3 seconds).
• The charger now examines the connected recharge-
able battery. In case of an error, a warning signal is
output and the corresponding information is displayed.
You can stop the warning signal by pressing the "BATT.
TYPE/STOP" button. You then return to the previous
configuration menu.
If no error is found, e.g. the display shown on the right
will appear.
The "R" value indicates the cell number that the charg-
er has recognised (in the example a 3-cell recharge-
able battery).
The "S" value indicates the cell number that you have
set in the menu (in the example also a 3-cell recharge-
able battery).
If these two numbers do not match, please check the settings on the charger and the
battery itself. It may be that the rechargeable battery has been completely discharged,
or a cell may be faulty. In this case, the battery should not be charged, as there is a
risk of fire and explosion!
You can return to the previous configuration menu using the "BATT. TYPE/STOP"
button.
• If the two cell numbers match, briefly push the "START/ENTER" button.
• Charging process starts. The display will show various
information on the current charging progress.
Example:
At the upper left, the rechargeable battery type and the cell number are displayed (e.g. "LP3s"
= LiPo rechargeable battery with 3 cells); the charging current is shown in the upper middle
and the current rechargeable battery voltage at the upper right.
The lower left shows the current rechargeable battery programme ("CHG" = "CHARGE"), in
the middle the elapsed charging time and the charged capacity in mAh are displayed to the
right of this.
84
BATTERY CHECK
WAIT...
R: 3SER
S: 3SER
CANCEL(STOP)
R: 3SER
S: 3SER
CONFIRM(ENTER)
LP3s 1.2A 12.32V
CHG 022:43 00682