Figure 5, wiring diagram External Balance Control Kit with internal 24 V power supply
5.3.2 External Balance Control Kit with external 24 V power supply
-
For use with an external 24 V DC power supply: Connect the Balance Control Kit as shown
in figure 6.
-
Use a 24 V DC (± 3V) power supply of at least 150 mA.
-
Connecting the "HV ON" output, "Overload" output and "Remote ON/OFF" input (remotely
ON/OFF switching of the high voltage) is optional.
The following steps describe how the "Remote ON/OFF" function, if desired, is activated:
-
DIP switch 1 on the inside of the MPM must be in the "ON" position in order to activate the
"Remote ON/OFF" option. (See also the MPM manual for more information).
-
The high voltage of the MPM is enabled when switch 1 or 2 is closed or when both switches
are closed.
Figure 6, wiring diagram External Balance Control Kit with external 24 V power supply
ExternalBalanceControlKit_MPM_UM_9752080710_NL_D_GB_F_V2_0
Switch 1
Switch 2
Jumper 1
Switch 1
Switch 2
Max. 50mA
Max. 50mA
Max. 50mA
Max. 50mA
34