DP8211/DP8212
Signalling of problems (with control panel DP8360 only)
When the battery power of the universal
transmitter becomes insufficient:
a press of the key test of the transmitter
doesn't cause the test LED to light anymore,
the control panel DP8360 memorises
the power problem and signals it:
- at the time of a disarm command: BEEP
FAULT SYSTEM,
- at the time of an arming: BEEP FAULT
BATTERY followed of the channel of the
non-supervised transmitters or BEEP FAULT
BATTERY followed of the type/zone number
the supervised intrusion transmitters,
to delete power supply problems of non-
supervised transmitters memorized by the
DP8360 control panel, you must erase the
whole fault memory of the control panel.
Supervised intrusion transmitters only:
after loss of the radio link or after a full
tamper alarm, the DP8360 control panel
memorises and signals the problem:
- at the time of a disarm command: BEEP
FAULT SYSTEM,
- at the time of arming: BEEP FAULT RADIO
or TAMPER then the type/zone number of
the supervised intrusion transmitters,
any anomalies from supervised intrusion
transmitters are automatically erased 15
mins maximum after the restore of the
transmitters fault.
GB