DP8211/DP8212
External wired contact, surface or flush
mounted D8923, D8931, D8932
Lid
Contact
Base
screwed
to the
5mm max
opening
leaf
Surface mounted
Universal transmitter
Frame
Opening
(secure side)
Flush mounted
Magnet
Possible
positions
Base screwed to the
for the magnet
opening leaf
Normally Closed loop type.
Wedges
D8931 (white) and D8932 (brown) tamper
alarm if the loop is cut:
- yellow and red wire: tamper loop,
- green and blue wire: detector loop.
When using tamper protected contacts,
cut the S link with side cutters on both
sides and remove it.
Surface mounted: align the contact and
magnet and screw them down (use wedges
if necessary).
Flush mounted:
- drill an 8 mm diameter, 30 mm deep hole
in both the frame and the opening leaf veri-
fy that the contact and the magnet are face
to face;
- Drill a hole in the frame for the contacts
cable.
Contact
Magnet
Incorrect
magnet
positions
Surface mounted contact with screw
terminals D8924
Magnet to
screw to the
opening leaf
Lid
Contact to screw
to the frame
5mm max.
Normally closed loop type.
Floor mount contact D8922
60mm max
Magnet to screw
to the opening leaf
Contact to screw
to the floor
Normally closed loop type.
GB