Télécharger Imprimer la page

DAITEM DP8000 Serie Mode D'emploi page 36

Emetteur universel
Masquer les pouces Voir aussi pour DP8000 Serie:

Publicité

Les langues disponibles

Les langues disponibles

P r e p a r a t i o n
Choice of contact
It is not possible to install Normally
!
Open and Normally Closed contacts
to the same universal transmitter:
If the integrated contact is used, only NC
external contacts can be connected,
If the external contact is NO, the
integrated contact can not be used.
Position
of micro-
switches
O
N
Integral contact only (NC)
1 2
O
Integral contact
N
+ external contact (NC)
1 2
O
External contacts only (NO/NC)
N
or roller shutter sensor
1 2
Positioning micro-switch 1 and 2
!
to ON is not permitted.
GB
36
Example for a supervised transmitter, on zone number 3, using the integral contact only
(normally closed type: NC)
Transmitter code
Program the chosen transmitter code (succession of 8 numbers composed of 0's and 1's)
by pressing the "0" and "1" buttons as indicated below:
Contact
1st press
simultaneously
hold until the LED
extinguishes
Start of programming
!
Channel or zone number
1
2
3
1
0
0
2nd press
simultaneously
hold until the LED
extinguishes
0
1
0
1
if during the programming, more than 7 seconds separate 2 key presses or if the
press of the "0" and "1" keys at the start or end of programming is not simultane-
ous or long enough, the detector ignores the programming: the LED blinks to indi-
cate the programming is incorrect. The code programmed initially is preserved. It is
necessary to restart the programming of the detector code from the beginning.
Operating
mode
4
5
6
1
1
1
8 short successive
Simultaneously press
presses
and hold until the LED
corresponding
extinguishes, then the LED
to the detection
lights for 5s to
code chosen
indicate correct
programming
. . .
End of programming
Type of
Type of
contact
sensor
7
8
0
0
0
1
Daitem

Publicité

loading

Ce manuel est également adapté pour:

Dp8211Dp8212