P r e p a r a t i o n
Verification of the
programming
Control panel in test mode (tamper switch
open):
To verify the power: press the detectors
test key and to verify that the test LED lights
to verify the programming of the operating
mode,
type of contact and type of sensor:
disconnect the lithium block for 1 minute,
reconnect the lithium block then, within
the following 30 seconds, verify the operat-
ing mode and sensitivity of detection by
pressing successively the "0" and "1" keys
as indicated below:
Press
LED
Off: non-supervised mode
0 button
Lit: supervised mode
Off: NC type
1 button
Lit: NO type
To verify the radio link, the installation
code and the channel (non-supervised
detection) press the test key of the transmit-
ter for at least 2 seconds:
correct: Sharp BEEP and lighting of the LED
corresponding to the selected channel for
that detector (followed by the announcement
of the channel of the detector with the
DP8360 control panel),
incorrect: warning BEEP from the control
panel or no BEEP at all.
to verify the radio link, the installation
code the type and the zone number pro-
grammed (supervised detector with the
DP8360 control panel) press the detectors
test key for at least 2 seconds:
correct: Sharp BEEP followed by the
announcement of the features of the trans-
mitter by the control panel,
incorrect: warning BEEP from the control
panel or no BEEP at all.
Learning
Solely for supervised intrusion transmitters
used with a DP8360 control panel. See the
procedure indicated on the label in the
access cover of the installer compartment
of the control panel.
When using contacts with tamper
!
protection, the activation of one of
the two tampers (loop or tamper
switch) renders the other inoperative.
I n s t a l l a t i o n
Cabling
For each universal transmitter, the number
of contacts is limited to 5 and the length of
each connection is 10m (out/return).
When using several contacts with one
universal transmitter:
NC type contacts: connect using serial
wiring,
NO type contacts: connect using parallel
wiring.
S
Series connection of 2 NC contacts with no tamper
S
Parallel connection of 2 NO contacts with no tamper
S
Series connection of 2 NC contacts with tamper
GB