AF-94
MODEL
HOW TO CHARGE THE COMBINATION AQUARIUM CARTRIDGE
1. Unscrew module cap.
2. Remove cup spring and cartridge plug.
3. Remove cartridge from module.
4. Fill inner cartridge core with coarse granular carbon or other media that will
not pass through the inner retainer screen.
5. Rinse carbon by letting water run down through open end of cartridge until
clear.
6. Install cartridge in filter module. Make sure cartridge fits onto center hub in
bottom of filter module. Cartridge should protrude about
7. Replace cartridge plug.
8. Install cup spring-large end over cartridge plug.
9. Before replacing module cap make sure O-ring is clean and lubricated with
Lifegard Silicone and in place.
START UP INSTRUCTIONS
1. Thread gauge adapter and air bleed into cap. Gauge adapter is sufficiently
tightened with 1 or 2 threads showing on inside of cap. Over-tightening will
break gauge adapter or interfere with cartridge. No not over-tighten. FINGER
TIGHTEN ONLY!
2. Open air bleeder beneath the pressure gauge.
3. Begin water flow through module.
4. Close air bleeder when a few drops of water are expelled.
5. To pre-determine the pressure at which to change the filter pleats, crimp the
return tube so that no water is allowed to flow back to the aquarium, then
record the pressure indicated (maximum pump output). The pleat change
pressure will be one or two psi less than the maximum reading just obtained.
It is recommended that the change pressure be marked with a piece of tape,
as it may be quite sometime before this pressure is reached.
WHEN TO CLEAN THE FILTER
1. When the gauge reaches the change pressure and/or when the water flow
has decreased considerably.
HOW TO CLEAN THE FILTER
1. Shut off pump.
2. Place clamps over inlet and outlet tubes below the level of the module cap.
3. Remove cap from module.
4. Remove cartridge, retainers from pleats, and pleats from cartridge. Carbon or
other media may be changed at this time.
5. Install new pleats by starting at the bottom of the cartridge and inserting one
pleat into each of the 30 V-shaped sections in the filter cartridge. When the
bottom of the filter pleats are completely seated, simply run your hand up the
filter pleats and the pleats will seat themselves along the entire cartridge.
Make sure the pleat retainers are seated properly.
6. To re-charge cartridge refer to numbers 1.-9.
7. Before replacing module caps, remove the O-ring and thoroughly clean it as
well as the O-ring seat and all threads. Coat the O-ring with Lifegard Silicone
and replace cap on the module and HAND TIGHTEN ONLY.
8. Remove clamp from inlet and outlet tubes, open the bleed valve on the pres-
sure gauge until a few drops of water are expelled, then close valve and start
pumping.
WARRANTY
PENTAIR AQUATICS warrants to the original purchaser of this equipment to be free from defects
in workmanship or material for a period of one year from the date of installation, provided this equip-
ment is installed in accordance with factory instructions and operated within the environment and lim-
itations for which it was designed.The pump, and Lifegard filter are covered under separate warranties
and copies of same are enclosed for your use. Should any of the integral parts of the unit become
defective within one year from date of purchase, they will be repaired or replaced, if proven defective
in workmanship or material in the opinion of the manufacturer.
PENTAIR AQUATICS, will not be liable for any labor cost of removing or replacing component
parts. This shall be the responsibility of the original purchaser, as will be all shipping charges to and
from the plant.
Damage or failure of any part of a unit covered by this warranty, which results from causes
directly, or indirectly connected with the installation, operation, environment, use or willful abuse,
including without limitation, improper repackaging and damage incurred in shipping, is not cov-
ered by this warranty. Unless state law provides otherwise, any implied warranties which accom-
pany the sale of these goods are limited to one year from date of installation.
Unless state law provides otherwise, manufacturer will only be responsible for repair or
replacement of any of its products or parts thereof that are found to be defective, and will not bear
the cost of any incidental or consequential damages arising out of the occurrence of such defect.
This warranty gives you specific legal rights and you may also have other rights which vary from
state to state.
MECHANICAL FILTER
1
/
" above module.
16
R172014 - CARTRIDGE PLUG
R175028 - PLEAT RETAINER
R175024 - COMBINATION
CARTRIDGE COMPLETE
SEE BELOW FOR MODELS
AF-94-19 AND AF-94-29
R175028 - PLEAT RETAINER
Model AF-94-19 and AF-94-29 do not use the combination
cartridge. When cleaning, remove center stand pipe,
clean and replace (refer to drawing)
MODELS AF-94-19
AF-94-29
ONLY
PLEATS ARE SAME AS MODULE AF-94
R172045B - PRESSURE GAUGE
R172045A - GAUGE ADAPTER
& AIR BLEED
R172012 - 3" CAP WITH ¼" HOLE
R172009 - CAP O RING
R172043 - CUP SPRING
R175026 - PLEAT ONLY
(STANDARD)
R175008 - ½" CLOSE NIPPLE
USED TO CONNECT
"T" MODULES
R270313 - ¾" CLOSE NIPPLE
R175025
AQUARIUM CARTRIDGE
COMPLETE HAS NO CARBON
RETAINER
AF-94-19 (2) REQUIRED
AF-94-29 (3) REQUIRED
CENTER STAND PIPE
R172018 FOR AF-94-19
R172017 FOR AF-94-29