CHARGING PROGRAM, LEAD ACID
DESULPHATION
15.8V
15.8V
Time limits
Max 8h
DESULPHATION
Detects sulphated batteries. Pulsing current and voltage, removes sulphate from the
lead plates of the battery restoring the battery capacity.
SOFT START
Tests if the battery can accept charge. This step prevents that charging proceeds with
a defect battery.
BULK
Charging with maximum current until approximately 80% battery capacity.
ABSORPTION
Charging with declining current to maximize up to 100% battery capacity.
12 • EN
SOFT START
BULK
Li-Ion
0.8A until 12.6V
Increasing voltage to
14.4V.
0.8A
5.0A until 12.6V
Increasing voltage to
14.7V.
5.0A
Max 20h
ABSORPTION
ANALYSE
Li-Ion
Li-Ion
Declining current.
Checks if voltage drops
14.4V
to 12V
Declining current.
Checks if voltage drops
14.7V
to 12V
Max 16h
ANALYSE
Tests if the battery can hold charge. Batteries that can not hold charge may need to
be replaced.
FLOAT
Maintaining the battery voltage at maximum level by providing a constant voltage
charge.
PULSE
Maintaining the battery at 95–100% capacity. The charger monitors the battery
voltage and gives a pulse when necessary to keep the battery fully charged.
FLOAT
Li-Ion
13.6V.
0.8A
13.6V.
5.0A
10 days. Charge cycle
3 min
restarts if voltage
drops.
PULSE
12.7–14.4V
0.8–0.4A
12.7–14.7V
5.0–2.5A
Charge cycle restarts
if voltage drops.