Description of the unit

FotoDent
polymerisation unit for post-curing of
FotoDent
gas. The protective gas atmosphere pre-
vents from the development of an inhi-

Putting into service

Before putting into service make sure
that no transport damages occurred.
Check for external damages at the
housing and control the glass plate on
the bottom of the polymerisation cham-
ber and the light tubes underneath.
Further ensure, that the indicated
voltage on the type plate meets the
voltage of the power source. Put the
with delivered connecting cable and
Information on using protective gas
By using protective gas it is possible
to do the polymerisation in an atmos-
phere without oxygen. The protective
gas replaces the air in the polymeri-
sation chamber and thus reduces the
oxygen content in the polymerisation
chamber of the FotoDent
ing to a curing of the FotoDent
without inhibition layer.
If the breaker is on „gas" the protective
gas supply is done automatically when
starting the polymerisation process. With
breaker position „0" the gas supply is
closed.
The flow rate is pre-set (120 l / h), if nec-
essary the adjustment can be changed
22
®
flash is a professional light
®
- materials by using protective
®
flash lead-
®
®
flash
bition layer on the surface of FotoDent
profiles. The programmable controller
of the FotoDent
tive menu navigation enable an easy
handling of the unit.
unit plug into the socket of the unit to
set up a power connection.
Safely fix the protective gas supply
pipe at the hose nozzle of the pres-
sure reducer of the gas pressure tank
with the help of the hose clamp. Create
a connection to the unit with the quick
coupler. The pressure must not exceed
5 bar (70 psi).
at the needle valve at the back of the
unit (observe safety instructions).If
modifying the output pressure of the
bottle at the pressure reducer of the
gas pressure tank the flow rate can be
changed without changing the needle
valve.
profiles
Pressure
bar
1
2
3
4
5
flash and the intui-
®
Flow rate
psi
14
28
42
52
70
®
l / h
60
80
100
120
140