• For post-curing of the parts, please select the parameter settings
for your process. You can find more qualified printers on our
website www.dreve.dentamid.de.
• Post curing:
PCU LED N
2
Rapid Shape D, DII / Asiga MAX UV
8 minutes, 80 % light
power (vacuum)
FotoDent® flash
Rapid Shape D, DII / Asiga MAX UV
8 minutes + 1 minute
gas pre-flow
RS Cure
Rapid Shape D, DII / Asiga MAX UV
8 minutes, 75 % light
power (vacuum)
• Impurity due to the construction or a break of the material and
impurity due to operation mistakes cannot be excluded. Thanks
to the low viscosity however it is possible to filtrate FotoDent®
setup. It is recommended to regularly take out the container of
the production unit, to homogenize and filtrate the content.
Upcoming entrained bubbles get eliminated through a holding
time of approx. 1–2 hour with FotoDent® setup.
To avoid damage of material quality do not expose the liq-
uid material to light under any circumstances. Variations from
the described manufacturing process may lead to modified
mechanical characteristics and/or colour variations of the Fo-
toDent® setup material.
Possible dangers
Please note the safety instructions for processing FotoDent® setup.
Hazard statements: H318 Causes serious eye damage. H317 May
cause an allergic skin reaction. H412 Harmful to aquatic life with
long lasting effects. H360D May damage the unborn child.
Precautionary statements: P261 Avoid breathing dust/fume/gas/
mist/vapours/spray. P280 Wear protective gloves/protective clothing/
eye protection/face protection. P305+P351+P338 IF IN EYES: Rinse
cautiously with water for several minutes. Remove contact lenses,
if present and easy to do. Continue rinsing. P310 Immediately call
a POISON CENTER/doctor. P501 Dispose of contents/container in
accordance with local/regional/national/international regulations.
Contains: 2-Propenoic acid, reaction product with Pentaerythrite,
1,4 Butanediol dimethacrylate, 2-benzyl-2-dimethylamino-4-mor-
pholinobutyrophenone, phenyl bis(2,4,6-trimethylbenzoyl)-phos-
phineoxide, Pigments
Lot number / Expiry date
The lot number and the expiry date are indicated on each FotoDent®
setup packaging. In case of claims please always indicate the lot
number of the product. Do not use the product after the expiry date.
Lieferform / Form of delivery
D35900
FotoDent® setup
1,0 kg Flasche / bottle
Rx only
Gefahr
Shake
Danger
before use
Stand der Informationen / Date of information: 03.2019
Dreve Dentamid GmbH
Max-Planck-Str. 31
59423 Unna/Germany
•
www.dentamid.dreve.de
dentamid@dreve.de
•
FotoDent® setup
385 nm / 405 nm
Gebrauchsanweisung / Directions for use
www.dentamid.dreve.de