Télécharger Imprimer la page

EdilKamin ECOIDRO Installation, Usage Et Maintenance page 30

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 42
Boiler-stove system as unique heat source, with water heater for domestic hot water production.
This layout is purely indicative. Have a plumber design and install the system.
CAUTION
domestic hot water production reduces the heating power of radiators.
ACCESSORIES
The diagrams above only include components available on the EdilKamin price list.
- Idrokit (pellet-fired) (code 601750): Complete apparatus for a simple and optimal installation, equipped with an elegant cover
for an exposed installation.
Idrokit allows hot sanitary water to be stored in the 50 litre boiler (supplied), which is always available at the desired temperatu-
re, even with the thermal stove turned off. The heating system water and the sanitary water can be managed separately through
the electronic panel.
An anti-legionella thermal disinfection system is installed so as to ensure safety.
Spare parts are also available (heat exchanger, valves, etc.).
1st IGNITION (Dealer)
Make sure that the plumbing has been correctly installed and fitted with a sufficiently sized expansion tank to assure safety.
The expansion tank built into the boiler-stove does not provide suitable protection against the thermal expansion of the water in
the whole system.
Turn the stove power supply on and carry out cold tests (Dealer).
Fill the system through the filling valve (do not exceed 1 bar in pressure).
While filling, "bleed" the pump and the bleed valve.
30
LEGENDA
ACS: Domestic Hot Water
AL: Water supply
B:
Water heater
C:
Filling/Topping up
EV2: Two-way solenoid valve
EV3: Three-way solenoid valve
NA: Normally Open
NC: Normally Closed
GR: Filling unit
MI: Outlet to system
P:
Pump (circulator)
RA: Radiators
RI:
Inlet from system
S:
Drain
TS: Boiler-Stove
V:
Ball valve
Vec: Closed Expansion Tank
VSP: Safety pressure valve

Publicité

loading