Miscellaneous

STATUS LED

When an error occurs with the unit, the ERROR LED on the front panel of the unit flashes or lights depending on the
error status, and the STATUS LED lights.
STATUS
1
2
3
The STATUS LED indicates the following error situations.
Error codes displayed during boot stage
(The ERROR LED blinks when an error occurs
during boot.)
Error
STATUS
ERROR LED Possible Cause
code
LED
1
Blinking
1 2 3 4
2
Blinking CPU fan failure
1 2 3 4
3
Blinking
1 2 3 4
4
Blinking CMOS battery failure
1 2 3 4
5
Blinking
1 2 3 4
6
Blinking
1 2 3 4
7
Blinking
1 2 3 4
8
Blinking
1 2 3 4
9
Blinking
1 2 3 4
A
Blinking
1 2 3 4
B
Blinking
1 2 3 4
C
Blinking
1 2 3 4
D
Blinking Reserved for future use
1 2 3 4
E
Blinking Reserved for future use
1 2 3 4
F
Blinking
1 2 3 4
indicates that the STATUS LED or ERROR LED is lit.
4
ERROR
Voltage power supply
failure
Defective memory
module
Video random access
memory (RAM) or
controller failure
Hard disk controller
failure
No bootable device
found
No bootable Operating
System found
One or more hard disk
failure
RAID OS volume
failure
Failure to start the X11
server
Failure to start the
application
RAID data volume
failure
Error codes displayed during operation stage
(The ERROR LED lights when an error occurs
during operation.)
Error
STATUS
ERROR
code
LED
LED
1
On
1 2 3 4
2
On
1 2 3 4
3
On
1 2 3 4
4
On
1 2 3 4
5
On
1 2 3 4
6
On
1 2 3 4
7
On
1 2 3 4
8
On
1 2 3 4
9
On
1 2 3 4
A
On
1 2 3 4
B
On
1 2 3 4
C
On
1 2 3 4
D
On
1 2 3 4
E
On
1 2 3 4
F
On
1 2 3 4
Possible Cause
Internal device temperature
problem
CPU fan failure
Power supply fan failure
Voltage power supply
failure
Hard disk fan 1 failure
Hard disk fan 2 failure
Hard disk is damaged.
Reserved for future use
Reserved for future use
Reserved for future use
Operating system error
Application functioning
failure
[ERROR] lamp in "Main"
screen is lit
RAID data volume failure
RAID data volume is being
restructured