Problem
Possible Cause
Air conditioner runs
for a short time only,
but room is not cool
Air conditioner runs,
but does not cool
Air conditioner
cycles on and off
too much
Temperature on
display does not
match room
temperature
Water drips from
cabinet into your
house
Water Full indicator
remains on, and the
air conditioner turns
off
12
Set temperature is close to
room temperature.
The filter is dirty or
obstructed by debris.
Air outlet is blocked.
Set temperature is too high. Lower set temperature.
The air conditioner has lost
charge (leak in system), or
operated in temperatures
below 64ºF (18ºC).
The air conditioner is set to
ComfortMode
control.
The air conditioner is not
properly sized for your
room.
The filter is dirty or
obstructed by debris.
There is excessive heat or
moisture (open container
cooking, showers, etc.) in
the room.
The louvers are blocked.
The outside temperature is
below 64°F (18°C).
The temperature of the
room you are trying to cool
is extremely hot.
Windows or doors to the
outside are open.
When the compressor and
fan motor turn off during
Power Saver mode, or after
you turn off the unit, a lower
temperature reading than
the actual room
temperature may be
displayed for a short period
of time.
The drain plug is not
installed properly.
This is normal.
Solution
Lower set temperature. See "Using the Controls."
Clean the filter.
Clear air outlet.
If the control buzzer beeps 3 times repeatedly, contact service technician.
Use ComfortMode
control only when you are asleep or away from home,
since the fan does not circulate the room air continuously.
Check the cooling capabilities of your portable air conditioner. Portable air
conditioners are not designed to cool multiple rooms.
Clean the filter.
Use a fan to exhaust heat or moisture from the room. Try not to use heat-
producing appliances during the hottest part of the day.
Install the air conditioner in a location where the louvers are free from curtains,
blinds, furniture, etc.
Do not try to operate your air conditioner in the cooling mode when the outside
temperature is below 64°F (18°C).
Allow extra time for the air conditioner to cool off a very hot room.
Close all windows and doors.
This lower temperature reading is caused by the temperature sensor being
located close to the cold evaporator coil. The actual room temperature will
display within a few minutes.
Install drain plug properly.
See "Portable Air Conditioner Care" for instructions on how
to drain the air conditioner.