Technical Data; Device Storage; Connecting The Power - Expondo S-SPOTTER 4000 Manuel D'utilisation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 22
Before welding, remove all flammable or explosive materials, such as propane/butane lighters or
matches.
Use face protection (helmet or shield) and eye protection, with a filter featuring a shade level matching
the sight of the welder and the welding current. The safety standards suggest colouring No. 9 (minimum
No. 8) for each current below 300 A. A lower colouring of the shield can be used if the arc is covered
by the workpiece.
Always use approved safety glasses with side protection under the helmet or any other cover.
Use guards for the welding operations site in order to protect other people from the blinding light
radiation or projections..
Always wear earplugs or another hearing protection to protect against excessive noise and to avoid
spatter entering the ears.
Bystanders should be warned to not look at the arc.
1.4. PROTECTION AGAINST ELECTRIC SHOCK
PLEASE NOTE: ELECTRIC SHOCK CAN BE LETHAL!
The power cable must be connected to the nearest socket and placed in a practical and secure position.
Positioning the cable negligently in the room and on a surface which was not checked must be avoided as
it can lead to electrocution or fire.
Touching electrically charged elements can cause electrocution or serious burns.
Electrical arc and the working area are electrically charged during the power flow.
Input circuit and inner power circuit of the devices are also under voltage charge when the power supply
is turned on.
The elements under the voltage charge must not be touched.
Dry, insulated gloves without any holes and protective clothing must be worn at all times.
Insulation mats or other insulation layers, big enough as not to allow for body contact with an object or
the floor, must be placed on the floor.
The electrical arc must not be touched.
Electrical power must be shut down prior to cleaning or electrode replacement.
It must be checked if the earthing cable is properly connected or the pin is correctly connected to the
earthed socket. Incorrect connection of the earthing can cause life or health hazard.
The power cables must be regularly checked for damage or lack of insulation. Damaged cables must be
replaced. Negligent insulation repair can cause death or serious injury.
The device must be turned off when it is not in use.
The cable mustn't be wrapped around the body.
A welded object must be properly grounded.
Only equipment in good condition can be used.
Damaged device elements must be repaired or replaced. Safety belts must be used when working at
height.
All fitting and safety elements must be stored in one place.
From the moment of turning on the release, the handle end must be kept away from the body.
The chassis ground must be mounted to the welded element or as close to it as possible (e.g. to a work
table).
THE DEVICE CAN STILL BE UNDER VOLTAGE UPON FEEDER DISCONNECTION.
The voltage in the input capacitor must be checked upon turning off the device and disconnecting it
from the power source. One must make sure that the voltage value is equal to zero. Otherwise, the
device elements must not be touched.
14
1.5 GASES AND FUMES
PLEASE NOTE: GAS MAY BE LETHAL OR DANGEROUS TO HUMAN HEALTH!
Always keep a certain distance from the gas outlet.
When welding, ensure good ventilation. Avoid inhalation of the gas.
Chemical substances (lubricants, solvents) must be removed from the surfaces of welded objects as
they burn and emit toxic smokes under the influence of temperature.
The welding of galvanised objects is permitted only when efficient ventilation is provided with filtration
and access to fresh air. Zinc fumes are very toxic, an intoxication symptom is the so called zinc fever.

2. TECHNICAL DATA

Product name
Model
Voltage [V]/frequency [Hz]
Input power [kW]
Rated input current [A]
Maximum current [A]
Weight [kg]
3. OPERATION
3.1 GENERAL NOTES
The device must be used according to its purpose, with observance of the OHS regulations and
restrictions resulting from data included in the rating plate (IP level, operation cycle, supply voltage,
etc.).
The machine must not be opened as it will cause warranty loss and, in addition, exploding, unshielded
elements can cause serious injuries.
The producer does not bear any responsibility for technical changes in the device or material losses
caused by the introduction of the said changes.
In case of incorrect device operation, contact the service centre.
Louvers must not be shielded – the welder must be positioned at 30 cm distance from objects
surrounding it.
The welder must not be kept under your arm or near to your body.
The machine must not be installed in rooms with aggressive environments, high dustiness and near
devices with high electromagnetic field emission.

3.2 DEVICE STORAGE

The machine must be protected against water and moisture.
The welder must not be positioned on heated surfaces.
The device must be stored in a dry and clean room..
3.3 CONNECTING THE DEVICE

3.3.1 CONNECTING THE POWER

The connection of the device must be performed by a qualified person. In addition, a person with
required qualifications should check if the earthing or electrical installation with protection system is
in accordance with the safety regulations and if they operate correctly.
The device must be placed near the work station.
The connection of excessively long conduits to the machine must be avoided.
One-phase welders should be connected to the socket fitted with an earthing prong.
Welders powered from a 3-Phase network are delivered without a plug, the plug must be obtained
independently and installation should be assigned to a qualified person.
Rev. 30.05.2017
Rev. 30.05.2017
Dent Puller Spot Welder
S-SPOTTER 4000
S-SPOTTER 5000
400~ 2 phase/50
16
19
42
50
4000
5000
58
64
S-SPOTTER 4200
18
47
4200
62
15

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

S-spotter 5000S-spotter 4200

Table des Matières