5.3.7 Preset 1
Preset 1 activated
Preset 1 disactivated and with-
out function
5.3.8 Shape of output 1
(only if preset 1 is activated)
Permanent signal. Is activated
at count value
Permanent signal. Will be-
come passive at count value
preset 1.
Timed signal. Will become
passive at count value
preset 1.
Timed signal. Is activated at
count value
5.3.9 Duration of the timed signal of output 1
(only if a timed signal has been
programmed in 5.3.8)
The duration can be set be-
tween 0.01 sec. and 99.99 sec.
A 0.00 setting is not accepted
5.3.10 Shape of output signal 2
Permanent signal. Is activated
at count value
Permanent signal. Will be-
come passive at count value
preset 2.
Timed signal. Will become
passive at count value
2.
Timed signal. Is activated at
count value
5.3.11 Duration of the timed signal of output 2
(only if a transient signal has been
programmed in 5.3.10)
5.3.12 End of programming
preset 1.
6. Setting of the presets
preset 1.
If a push-button with an arrow or the "P" push-but-
ton is pressed, the device jumps from the display
of the counter to the display of the preset 1. A
second operation of push-button "P" switches to
the preset 2. About 4 seconds after the last opera-
tion of a push-button the device jumps back to the
display of the counter and takes over a new preset
value.
Exception: in the time counter mode, the new
value is taken over immediately.
Once the preset is displayed, the " " push-button
allows to choose the decade to be modified. This
decade then blinks at a 1 Hz frequency. The ""
push-button allows you to raise the value of the
decade. On the most significant decade, after the
value "9", the sign "-" is displayed. The following
operation of the "" push-button displays "-1"
preset 2.
again. A new operation of the "" push-button lets
the display of this decade start again at "0".
Caution: in case of automatic repetition, preset 2
cannot be given negative values.
preset
preset 2.
The duration can be set be-
tween 0,01 sec. and 99,99 sec.
A 0.00 setting is not accepted
Programming is carried out
once more. The values input
can be checked and modified.
Programming is complete and
the values input are taken over
as new parameters. Then the
device is ready for operation.
9