For the setting of the numerical values, like
for instance the scale factor, see also 6. Set-
ting of the preset.
5. Programming mode
The first parameter of the menu is the selection of
the operating mode.
Mode pulse counter. See 5.1.
Mode time counter. See 5.2.
Mode frequency meter. See 5.3.
5.1 Pulse counter mode setting
5.1.1 Sub-operating mode
Adding
Outputs active at count
value
Resetting to zero
Subtracting
Output 1 active at count
value
Output 2 active at count
value
Resetting to preset 2
Adding
Outputs active at count
value
Automatic reset to zero at count
value = preset 2
Resetting to zero
Subtracting
Output 1 active at count
value
Output 2 active at count
value = 0
Automatic positioning to preset
2 at count value = 0
Resetting to preset 2
4
preset
preset 1
0
preset
preset 1
5.1.2 Polarity of the inputs
npn: switching to 0 V
pnp: switching to +24 V
5.1.3 Activation of the 30 Hz filter
max. counting frequency: 20
kHz
max. counting frequency: 30 Hz
5.1.4 Input modes
Counting and counting direc-
tion inputs
INP A: counting input
INP B: counting direction input
Differential counting input
INP A: adding counting input
INP B: subtracting counting
input
Phase discriminator
INP A: 0° counting input
INP B: 90° counting input
Phase discriminator with
multiplication of the pulses
by two
INP A: 0° counting input
INP B: 90° counting input
Each INP A pulse edge is con-
sidered
5.1.5 Setting of the scale factor
Scale factor setting range from
00.0001 to 99.9999. Fixed deci-
mal point set to 4 decimal
places.
A "0" setting is not accepted.