5.1.13 End of programming
Programming is carried out
once more. The values input
can be checked and modified.
Programming is complete and
the values input are taken over
as new parameters.
Then the device is ready for op-
eration.
5.2 Time meter mode setting
5.2.1 Sub operating mode
Adding
Outputs active at count
value
Resetting to zero
Subtracting
Output 1 active at count
value
Output 2 active at count
value
Resetting to preset 2
Adding
Outputs active at count
value
Automatic reset to zero at count
value = preset 2
Resetting to zero
Subtracting
Output 1 active at count
value
Output 2 active at count
value = 0
Automatic positioning to preset
2 at count value = 0
Resetting to preset 2
6
preset
preset 1
0
preset
preset 1
5.2.2 Polarity of the inputs
npn: switching to 0 V
pnp: switching to +24 V
5.2.3 Activation of the 30 Hz filter
Electronic input dviving
Mechanical input driving
5.2.4 Start and stop of time counting
A pulse on INP B starts the
counting, the following pulse on
INP B stops it (raising pulse
edge for pnp, descending pulse
edge for npn).
A pulse on INP A starts the
counting, a pulse on INP B
stops it (raising pulse edge for
pnp, descending pulse edge for
npn).
The counting can only be con-
trolled by means of the GATE
input. INP A and INP B have no
function.
The counter is reset by a reset
signal (manual or electrical) (to
0 when adding, to preset 2
when subtracting), then count-
ing starts. Counting is stopped
when the adding counting
reaches preset 2 or when the
subtracting counting reaches 0.
A reset signal during counting
also stops the counting. INP A
and INP B have no function.