Technical data
Charger
Power supply (input)
Mains frequency
Charging voltage (out
put)
Rapid charging
Charging times for BP, BPS and BPC battery packs, approx.
1.5 Ah
2.6 Ah
4.2 Ah
3.1 Ah*
4.0 Ah*
5.2 Ah*
6.2 Ah*
Permitted charging
temperature range of
the battery pack
Temperature monitoring
3
Symbols
Warning of general danger
Warning of electric shock
Read the operating instructions and
safety instructions.
Read the operating manual and safety
warnings.
For indoor use only
Fuse with specification of current value
T
Safety transformers
12
TCL 6
220–240 V~
50–60 Hz
10.8–18 V
Max. 6 A
26 min.
46 min.
76 min.
33 min.
32 min.
45 min.
53 min.
TCL 6 DUO
220–240 V~
50–60 Hz
Output1: 10.8–18 V
Output2: 10.8–18 V
Output1: Max. 6 A
Output2: Max. 6 A
26 min.
46 min.
76 min.
33 min.
32 min.
45 min.
53 min.
-5 °C to +55 °C
via NTC resistor
Safety class II
Do not dispose of it with domestic
waste.
Do not dispose of it with domestic
waste.
Handling instruction
UKCA marking: The United Kingdom
Conformity Assessed symbol is a
marking for products being placed on
the market in the United Kingdom. It is
a manufacturers indication that the
product is in conformance with the rel
evant regulations in the UK.
SCA 8
220–240 V~
50–60 Hz
10.8–18 V
Max. 8 A
26 min.
46 min.
76 min.
33 min.
32 min.
33 min.
40 min.