4.3
Connecting the wastewater pump(s)
1 Before connecting the pump, check whether the control unit's motor
protection switch is suitable for the current consumption of the pump(s) (see
nameplate).
▶ Adjust the motor protection switch to the pump's nominal current (see
pump's nameplate)
▶ Pull the connection cable through the housing opening(s).
▶ Establish the connections in accordance with the connection diagram (in
the housing cover of the control unit).
The control unit has a terminal block in which the terminal pairs for the thermal
contact (TF 1 and TF 2) share a common terminal in the middle.
Wastewater pump connection [3]
- 1 - 3 Phases
- 4 + 5 Winding temperature switch
- 5 + 6 Temperature monitoring*
- 7 PE (protective earth)
TF1*: Connection for temperature monitoring, self-resetting
TF2*: Connection for NON-self-resetting thermal cutoff
(for ATEX)
In the case of pumps with only one temperature monitoring, bridge
the terminal [3a] or [3b] of the non-existent type of monitoring. Pay
attention to the ATEX regulations!
010-532_03
ATEX:
Installation and operating manual
TF2*
TF1*
1
[3]
ATEX:
TF2*
TF1*
1
[3a]
TF2*
TF1*
1
[3b]
47