Télécharger Imprimer la page

Maintenance - L.B. White Sun Blast CR015 Manuel D'utilisation Et De Pièces Detachées

Publicité

Les langues disponibles

Les langues disponibles

Sun Blast Operating Instructions and Parts Manual
Sun Blast
Construction Heater
Operation - Lighting Under
Wind Conditions
E
N
When using this heater outdoors on a
G
windy day, it will be necessary to use a
match or long stem butane lighter to
L
ignite the burner. It may be difficult to
I
keep the match lit long enough under
S
windy conditions. Follow the "Lighting
H
instructions when Using a Match"
procedure after doing the following:
1. Position the heater and cylinder such
that the burner faces away from the
wind.
2. Position your body behind the heater
such that your body blocks the
wind while you are following the
instructions for lighting with a match.
Operation - Turning Off
Heater
1. Tightly close propane tank valve by
turning fully clockwise
2. Turn the heater regulator knob to the
"OFF" (
) position. Wait at least 30
minutes for the heater to cool before
handling heater.
3. Always remove the heater from the
propane tank after eachSun Blast use
and store indoors. Do not store heater
while attached to propane tank.
Do not store propane cylinders in a
building, garage or any other enclosed
area.
VENTILATION
Always be sure to supply proper
ventilation while operating heater.
Provide a minimum of 1/2 square foot
opening for fresh air supply for 15,000
BTU's of heat and one square foot
opening for 30,000 BTU's of heat.
Storage
Never store a Propane gas tank inside a
building or in the vicinity of any gas or
Propane Tank Top
®
Figure 5
Ignition Hole
Tip Over Switch
Air Inlet Hole
Safety
Shut-off Valve
Model CR030
oil burning appliance. Always remove
the heater from the propane tank after
each use and store indoors. Do not store
heater while attached to propane tank.
Do not store propane cylinders in a
building, garage or any other enclosed
area. The tank must be disconnected
and stored outdoors in a well ventilated
.
area out of reach of children, in
accordance with the standard for the
the Storage and Handling of Liquefied
Petroleum Gases, ANSI / NFPA 58 and
CSA B149.1, Natural Gas and Propane
Installation Code. The plastic tank valve
plug supplied with your tank must
be tightly installed when the tank is
disconnected from the heater.
Maintenance Instructions
1. Turn unit off, allow heater to fully
cool and disconnect propane hose
before performing any Maintenance
functions.
2. Keep unit clean and keep the inside of
the unit debris free.
3. Have unit checked by a qualified
technician at least once a year,
preferably prior to the heating season.
NEVER LEAVE THE HEATER
UNATTENDED WHILE BURNING!
8
CR015 and CR030

Publicité

loading

Ce manuel est également adapté pour:

Sun blast cr030