NEVER LEAVE THE HEATER
UNATTENDED WHILE BURNING!

Checking for Leaks

Check all gas connections with a 50/50
soap and water solution to be sure they
are tight and leak proof. The formation
of bubbles indicate a gas leak. Correct
all leaks before using the heater.
• The installation of your heater must
meet all local codes and/or gas utility
requirements or, in the absence of
local codes, with the Storage and
Handling of Liquefied Petroleum
Gases, ANSI/NFPA 58 and the Natural
and Propane Installation Code, CSA
B149.1.
• The minimum clearances to
combustible construction: Side
and Rear- 36" (91cm); Top - 36"
(91cm); Front - 60" (150cm); Floor -
combustible, must be maintained
at all times. Not for use on finished
floors.
• The hose assembly should be visually
inspected prior to each use of the
heater. If it is evident that there
is excessive abrasion or wear, or
the hose is cut, it must be replaced
prior to the heater being put into
operation.
• The replacement hose assembly shall
be that specified by the manufacturer.
Never use an open
WARNING
flame to check for
leaks.
Operation - Lighting
Instructions Using a Match
Read and understand all safety
information before operating
heater.
Burner and Burner
WARNING
Guard should always
face away from propane tank shut-off
and regulator.
Improper installation,
WARNING
alteration, service or
maintenance can cause property
damage, injury or death. Read the
installation, operating and maintenance
instructions thoroughly before
installing or servicing this equipment.
Do not cover air inlet
WARNING
holes in mixing tube.
Make sure there is no
WARNING
open flame in the
area. Fully open the propane tank valve.
1. Open Cylinder valve by turning
COUNTERCLOCKWISE
2. Turn heater regulator knob
CLOCKWISE
to the "High"
(
) position. (Fig. 4).
Stand to the side of
WARNING
unit while lighting.
Do not stand or have any part of your
body over or in front of heater while
lighting.
3. Do not attempt to light one burner
off of the other. Use one match per
burner. Locate ignition hole in side
of burner. (Fig. 5) Insert a lit match
through ignition hole.
Do not insert match
CAUTION
into air inlet holes in
mixing tube.
4. Push in the safety shut-off valve
plunger (Fig. 5).
Do not push in safety
WARNING
shut-off valve
plunger before inserting lit match.
5. Burner should light. Mesh screen
on burner glows red when lit. After
burner is lit, continue holding in safety
shut-off valve plunger (about 10 to 30
seconds) until heater stays lit.
6. If the burner does not light within 10
seconds, turn regulator knob to the
"OFF" (
) position. Wait at least five
(5) minutes for the gas to dissipate
before relighting.
7. If heater will not light after repeated
tries, do not attempt to repair heater.
7
Call technical support at 800-345-7200.
8. After burner lights, turn the heater
regulator knob to the desired heat
setting "LOW" ( ), "MED" (
"HIGH" (
).
9. For model CR030 only : Light both
burners when maximum heat is
needed. Use one burner to conserve
fuel. Repeat steps to light second
burner.
Figure 4
.
Burner Front
Ignition Hole
Wing Bolt
Safety
Shut-off Valve
Heat Regulator Knob
Support Leg
Model CR015
E
N
), or
G
L
I
S
H
Electrode

Publicité

loading

Ce manuel est également adapté pour:

Sun blast cr030